Fault description Cause
Remedy
0001 = Output triggered
1310
Output valve vibration high amplitude, Y 57 Display value = output voltage in Volt
Voltage at output
Display value = output voltage in Volt
1311
Output valve vibration high amplitude, Y 57 Display value = output current in Amperè
Current at output
Display value = output current in Amperè
1312
Output valve vibration high amplitude, Y 57 0000 = Output not triggered
0001 = Output triggered
Logic level of control
0000 = Output not triggered
0001 = Output triggered
Fault descrip-
tion
Cause
Remedy
1400
Input signal L from generator regulator
12 V > Generator stopped
Ground, 0 V > Generator running
1401
Input oil pressure switch, B 06
12 V > No oil pressure
Ground, 0 V > Oil pressure
1402
Input limit switch engine speed solenoid,
Aux
12 V > Solenoid retracted
0V Ground > Solenoid not in end position
1405
Input inclination sensor, B 56
12 V > Inclination less than 45°
0V Ground > Inclination higher than 45°
1409
Activation input, cable remote control, S
101
12 V > Operating mode cable remote control
1410
Activation input, radio remote control, S
101
12 V > Operating mode wireless
Fault
description
Cause
Remedy
5010
Engine speed
Display value = 1/min
5020
Engine oil pressure, B 06
0000 = No engine oil pressure
0001 = Engine oil pressure OK
Shows status of input engine oil
pressure
0000 = No engine oil pressure
0001 = Engine oil pressure OK
5030
Inclination sensor, B 56
0000 = No signal, machine inclined more than 45°, or
switch defective
Inputs logic and power module
Diesel engine, machine electrics
Appendix – Input codes for BLM control
D.ONE
183
Содержание D.ONE
Страница 2: ...2...
Страница 7: ...1 Introduction Introduction D ONE 7...
Страница 11: ...2 Technical data Technical data D ONE 11...
Страница 16: ...Technical data Noise data D ONE 16...
Страница 17: ...3 Concerning your safety Concerning your safety D ONE 17...
Страница 50: ...Concerning your safety Signage D ONE 50...
Страница 51: ...4 Indicators and control elements Indicators and control elements D ONE 51...
Страница 60: ...Indicators and control elements Remote control D ONE 60...
Страница 61: ...5 Checks prior to start up Checks prior to start up D ONE 61...
Страница 69: ...6 Operation Operation D ONE 69...
Страница 95: ...7 Loading transporting the machine Loading transporting the machine D ONE 95...
Страница 101: ...8 Maintenance Maintenance D ONE 101...
Страница 142: ...Maintenance As required D ONE 142...
Страница 143: ...9 Setting up refitting Setting up refitting D ONE 143...
Страница 148: ...Setting up refitting Teaching the BOSS safety field system D ONE 148...
Страница 149: ...10 Troubleshooting Troubleshooting D ONE 149...
Страница 167: ...11 Disposal Disposal D ONE 167...
Страница 169: ...12 Appendix Appendix D ONE 169...
Страница 189: ......
Страница 190: ......