Code Fault reaction
Description of fault
Possible cause
Ter-
minal
on
BLM
Input
code for
diag-
nose
2021 Output is switched
off, function no
longer possible
Output valve steering left, Y
238
Short-circuit current flow out
of this output Output was
switched off!
Short circuit to ground in
the current path
Lines rubbed through
Valve defective
X3:21
-
2022 Output is switched
off, function no
longer possible
Output valve steering left, Y
238
No or too low current flow out
of this output
Wire breakage in current
path
Current path connected to
+12V
X3:21
1020
1021
1022
2023 Engine is shut
down
Output valve steering left, Y
238
Although the output is
switched off, voltage is
present
Current path connected to
+12V
X3:21
1020
1021
1022
Code
Fault reaction
Description of fault
Possible cause
2500
Engine is stopped, all functions
are locked, horn sounds
Operation of two remote
control system at the
same time
A remote control with
cable and a wireless
remote control are oper-
ated at the same time.
2600
Engine stopped, emergency stop
relay in the control is switched
off, all outputs on control are
switched off
Remote control emer-
gency stop
Emergency stop on
remote control operated
2601
Engine stopped, emergency stop
relay in the control is switched
off, all outputs on control are
switched off
Fault in data transfer
between remote control
sender and receiver
Battery empty
Radio signal transmission
is disturbed
Distance between sender
an machine too big
2605
Output of error
code 2605 only with
software version older
than 1.11!
Engine stopped, emergency stop
relay in the control is switched
off, all outputs on control are
switched off
Receive signal too weak
Radio signal transmission
is disturbed
Distance between sender
an machine too big
2611
Engine is shut down.
CANopen – fault in bus
communication
2612
Engine is shut down.
CANopen – fault in bus
communication
2613
Engine is shut down
CANopen – fault in bus
communication
Fault codes of remote control
Appendix – List of fault codes
D.ONE
174
Содержание D.ONE
Страница 2: ...2...
Страница 7: ...1 Introduction Introduction D ONE 7...
Страница 11: ...2 Technical data Technical data D ONE 11...
Страница 16: ...Technical data Noise data D ONE 16...
Страница 17: ...3 Concerning your safety Concerning your safety D ONE 17...
Страница 50: ...Concerning your safety Signage D ONE 50...
Страница 51: ...4 Indicators and control elements Indicators and control elements D ONE 51...
Страница 60: ...Indicators and control elements Remote control D ONE 60...
Страница 61: ...5 Checks prior to start up Checks prior to start up D ONE 61...
Страница 69: ...6 Operation Operation D ONE 69...
Страница 95: ...7 Loading transporting the machine Loading transporting the machine D ONE 95...
Страница 101: ...8 Maintenance Maintenance D ONE 101...
Страница 142: ...Maintenance As required D ONE 142...
Страница 143: ...9 Setting up refitting Setting up refitting D ONE 143...
Страница 148: ...Setting up refitting Teaching the BOSS safety field system D ONE 148...
Страница 149: ...10 Troubleshooting Troubleshooting D ONE 149...
Страница 167: ...11 Disposal Disposal D ONE 167...
Страница 169: ...12 Appendix Appendix D ONE 169...
Страница 189: ......
Страница 190: ......