EC-2000-CES MANUAL
59
206
Press movement in wrong direction fault
. Press movement in wrong direction contrary
as set by parameter I.3 (wrong direction degrees)
Possible causes:
-
Improper or loose wiring of resolver check and repair.
-
Incorrect setting of parameter F.19 (For-Rev Resolver).
-
Loose plug in resolver chip on brake board – re-seat.
-
At top, falling back, holding brake not adjusted properly.
-
Motor is running in wrong direction.
-
Defective Brake control board.
207
Loss of line fault
. Loss of one phase or greater than 20% drop in voltage for greater
than 100 milliseconds.
Possible causes:
-
Input line fuse blown.
-
Brake control board fuse blown.
-
Loss of a single phase.
-
Defective brake control board
-
Low voltage – check incoming line.
208
Enables without clutch contactor on fault.
“clutch on” (wire 10) signal is not present
within time set in H.2 of receiving enables.
Possible causes:
-
Press control not sending signal. Check clutch on LED on brake control board.
-
Bad clutch brake board
-
Parameter H.2. Time set too short.
209
Clutch contactor on after clutch on is a de-energized fault
. Clutch on signal (10) is
present longer than tie set in H.3
Possible causes:
-
Clutch contactor welded
-
Clutch contactor auxiliary contact stuck on.
-
Defective brake board input.
-
Parameter H.3. Time set too short.
210
Missing enable low fault.
The two enable signals are not coincident for more than time
listed in parameter H.2.
Possible causes:
-
Press control not sending signal. Check clutch on LED on brake control board.
-
Bad clutch brake control board.
-
Parameter H.2. Time set too short.
Содержание 015-000248-2002
Страница 7: ...EC 2000 CES MANUAL 7 Figure 1 Eddy Current Drive Block Diagram ...
Страница 8: ...EC 2000 CES MANUAL 8 Figure 2 EC 2000 CES Keypad Display ...
Страница 12: ...EC 2000 CES MANUAL 12 ...
Страница 16: ...EC 2000 CES MANUAL 16 Figure 4 Keypad Cutout Template to Scale Inches ...
Страница 17: ...EC 2000 CES MANUAL 17 Figure 5 Keypad Dimensions to Scale ...