EC-2000-CES MANUAL
41
The inch mode will be indicated by display of the "Inch H" on the keypad display.
INCH REVERSE MODE (SET UP)
The controller will be in the inch reverse mode if the following conditions exist:
1. Enable signals are present
2. No fault is present
3. Reverse is not present
4. Inch is present
5. Micro inch is not present
6. Clutch contactor ON signal is present
7. Brake contactor is closed
8. The main motor is programmed to run in the reverse direction
When in the inch reverse mode, the controller functions in the following manner.
A clutch ON command with enables closes the clutch contactor. Upon initiation of the run mode,
the control reference signal ramps up from zero at the inch acceleration rate parameter C.3, until
the drive reference equals programmed reference parameter F.1). When the enables are
released the control reference ramps down according to the stop deceleration rate Parameter C.4
to zero set point is reached. At the time the enable is removed, the clutch timer is initiated. After
the delay time is reached, the clutch contactor is dropped out by control removing clutch on or the
internal brake delay timing out (parameter D.10).
The inch reverse mode will be indicated by simultaneous display of the "Inch H" and “Reverse" on
the keypad display.
MICRO INCH FORWARD MODE (SET UP)
The controller will be in the micro inch forward mode if the following conditions exist:
1. Enable signals are present
2. No fault is present
3. Reverse is not present
4. Micro Inch is present
5. Inch is not present
6. Clutch contactor ON signal is present
7. Brake contactor is closed
When in the micro inch forward mode, the controller functions in the following manner:
A clutch ON command with enables closes the clutch contactor. Upon initiation of the run mode,
the control reference signal ramps up from zero at the inch acceleration rate parameter C.3, until
the drive reference equals programmed reference parameter F.2). When the enables are
released the control reference ramps down according to the stop deceleration rate Parameter C.4
to zero set point is reached. At the time the enable is removed, the clutch timer is initiated. After
the delay time is reached, the clutch contactor is dropped out by control removing clutch on or the
internal brake delay timing out (parameter D.10).
The micro inch mode will be indicated by display of the "Inch L" on the keypad display.
Содержание 015-000248-2002
Страница 7: ...EC 2000 CES MANUAL 7 Figure 1 Eddy Current Drive Block Diagram ...
Страница 8: ...EC 2000 CES MANUAL 8 Figure 2 EC 2000 CES Keypad Display ...
Страница 12: ...EC 2000 CES MANUAL 12 ...
Страница 16: ...EC 2000 CES MANUAL 16 Figure 4 Keypad Cutout Template to Scale Inches ...
Страница 17: ...EC 2000 CES MANUAL 17 Figure 5 Keypad Dimensions to Scale ...