12.5 SERIAL PORT FAULT REPORT DATA PACKET CONTENT
Table 9
: Control Fault Data Format
12.6 SERIAL PORT MONITOR DATA INSTRUCTION
Monitor data will be sent by the DMR on request of the press control. The two ASCII characters of the
"Request to Send Monitor Data" will be CC. The packet length of the request will be two characters.
The DMR will then send the monitor data in a packet of bits representing ASCII characters. The first two
ASCII characters will be CC. The remaining characters will contain the monitor data. Zeros are used to
complete the 68-character packet. Numbers in the monitor data will be four digits with an implied
decimal point.
12.7 SERIAL PORT MONITOR DATA PACKET CONTENT
The CES monitor data packet will contain the following information:
1. ASCII characters CC.
2. Acceleration and deceleration rates will be four digits, with an implied decimal point, in tenths of a
stroke.
3. The speeds will be four digits, with an implied decimal point, in hundredths of a stroke per minute.
4. The CES monitor data will have the format indicated in Table 10 (Next Page) per minute per second.
Packet Number
Data
1 through 2
BB
3 through 6
Current Fault
7 through 10
Prior Fault #1
11 through 14
Prior Fault #2
15 through 18
Prior Fault #3
19 through 22
Prior Fault #4
23 through 68
Zeros
Содержание 015-000248-2002
Страница 7: ...EC 2000 CES MANUAL 7 Figure 1 Eddy Current Drive Block Diagram ...
Страница 8: ...EC 2000 CES MANUAL 8 Figure 2 EC 2000 CES Keypad Display ...
Страница 12: ...EC 2000 CES MANUAL 12 ...
Страница 16: ...EC 2000 CES MANUAL 16 Figure 4 Keypad Cutout Template to Scale Inches ...
Страница 17: ...EC 2000 CES MANUAL 17 Figure 5 Keypad Dimensions to Scale ...