M
icro inch change fault.
If the micro inch command is changed while the enable is
present this fault will occur.
Possible Causes:
-
Check operator error or interface problem. Check LED
-
Input module for micro inch command.
-
Defective brake control board
319
Reverse change fault.
If the reverse command is changed while the enable is present
this fault will occur.
Possible Causes:
-
Check operator error or interface problem. Check LED
-
Input module for reverse command.
-
Defective brake board.
329
Parameter out of limit fault.
If a parameter downloaded via the serial interface is out
of the established limits, this fault will occur.
Possible causes:
-
Operator or interface error .
-
Defective brake control board
Control fault:
a microprocessor watchdog timer monitors the microprocessor and the power
supply for proper operation. This fault requires turning power to the control off to reset.
Possible causes:
-
Power supply 5V Adjustment clutch control board.
-
Power supply 5V Adjustment brake control board.
-
Defective clutch control board
-
Defective brake control board.
13.4 TROUBLE SHOOTING. NO FAULT DISPLAYED:
13.41 Blank Display:
Possible causes:
-
Processor Crashed. Cycle control Power
-
Power supply 5V Adjustment brake control board. Adjust to 5.000 v +-1%
-
Defective RS-232 Data Splitter
-
Defective RS-422 Data Converter
-
Defective Keypad Display.
-
Bad cable connections
-
Defective brake control board
-
Blown Fuses on brake control board
Содержание 015-000248-2002
Страница 7: ...EC 2000 CES MANUAL 7 Figure 1 Eddy Current Drive Block Diagram ...
Страница 8: ...EC 2000 CES MANUAL 8 Figure 2 EC 2000 CES Keypad Display ...
Страница 12: ...EC 2000 CES MANUAL 12 ...
Страница 16: ...EC 2000 CES MANUAL 16 Figure 4 Keypad Cutout Template to Scale Inches ...
Страница 17: ...EC 2000 CES MANUAL 17 Figure 5 Keypad Dimensions to Scale ...