Table 10:
Control Monitor Data Format
12.8 SERIAL PORT CONNECTIONS
Note: The Serial Port Connections on the CES Controller are as follows:
TX+ = 91 Old(322)
TX- = 92 Old(323)
RX- = 93 Old(324)
RX+ = 94 Old(325)
The Proper baud rate must also be set. It is 9600.
Packet Number
Data
1 through 2
CC
3 through 6
Inch Speed
7 through 10
Micro Inch Speed
11 through 14
Creep Speed
15 through 18
Auto acceleration rate
19 through 22
Auto deceleration rate
23 through 26
Manual acceleration rate
27 through 30
Manual deceleration rate
31 through 34
Stop Deceleration Rate
35 through 68
Zeros