EC-2000-CES MANUAL
50
o
Time = Parameter Group H, Item 15
FAULT 229 Brake Contactor Open
o
In normal operation the brake contactor is closed. If it opens for the programmed time
a fault is set.
o
Parameter Group H, Item 1
FAULT 231 Controller Internal Communication Error
o
The controller has two microprocessors. The master processor handles everything
except for speed and current control. The control processor handles speed and current
control. It accepts speed and run commands from the master control and reports
current and speed values to the main processor several times per second. If no data is
received by the master processor for the programmed time, a control fault is set.
o
Time = Parameter Group H, Item 23.
11.03 LEVEL 300 FAULTS
Stop On Top Faults
FAULT 313 Under Speed Fault
o
Over Speed Fault occurs when drive speed is under the set point by the % of span set in
under speed trip % for the time set in over speed trip time.
o
Time-% Parameters- Group H, Items 18 & 19.
FAULT 314 Clutch and Brake Current Overlap
o
If both the clutch and brake values exceed 20% of max current at the same time for the
time set in the programmed parameter a fault is set.
o
Time = Parameter Group H, Item 9.
FAULT 315 Clutch Over Current
o
If the clutch current exceeds the maximum limit value for the programmed period of
time this fault is set.
o
Time = Parameter Group H, Item 7
FAULT 316 Brake Over Current
o
If the brake current exceeds the maximum limit value for the programmed period of
time this fault is set.
o
Time = Parameter Group H, Item 8
FAULT 317 Inch Command Change
o
If the Inch command is changed while the drive is run mode and the programmed
period of time has passed this fault is set.
o
Time = Parameter Group H, Item 6
FAULT 318 Micro Inch Command Change
o
If the Micro Inch command is changed while the drive is run mode and the
programmed period of time has passed this fault is set.
o
Time = Parameter Group H, Item 6
FAULT 319 Reverse Command Change
o
If the Reverse command is changed while the drive is run mode and the programmed
period of time has passed this fault is set.
o
Time = Parameter Group H, Item 6
FAULT 320 Clutch Current On Too Long
Содержание 015-000248-2002
Страница 7: ...EC 2000 CES MANUAL 7 Figure 1 Eddy Current Drive Block Diagram ...
Страница 8: ...EC 2000 CES MANUAL 8 Figure 2 EC 2000 CES Keypad Display ...
Страница 12: ...EC 2000 CES MANUAL 12 ...
Страница 16: ...EC 2000 CES MANUAL 16 Figure 4 Keypad Cutout Template to Scale Inches ...
Страница 17: ...EC 2000 CES MANUAL 17 Figure 5 Keypad Dimensions to Scale ...