![Dynalab NX Series Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/dynalab/nx-series/nx-series_user-manual_2547775031.webp)
Dynalab Test Systems
NX Tester User’s Guide
29
Copyright 2011
Revised 04/27/2011
SPEED
Continuity only
A 1024 point wire harness can be tested in one second
Continuity & Shorts
A 1024 point wire harness can be tested for continuity and shorts in
three seconds
ELECTRICAL SPECIFICATIONS
Input Power
Uses external power supply rated for 100 – 240VAC, 50-60Hz.
Power supply provides 15VDC to the NX Tester.
Test Voltage
Test voltage is automatically selected by the NX Tester. The
maximum voltage is 14VDC.
Test Current
Test current is automatically selected by the NX Tester. The
maximum test current is 5mA DC.
PHYSICAL SPECIFICATIONS
Test Point Capacity
NX Solo: 128 – 256
NX Pro: 128 – 512
NX Pro+: 128 - 32768
Dimensions (W x D x H)
NX Solo: 10.7” x 7.5” x 3” (21 cm x 19 cm x 8 cm)
NX Pro: 10.7” x 7.5” x 4” (21cm x 19 cm x 10 cm)
NX Pro+ Expansion Unit: 9.5” x 6.4” x 6.3” (24cm x 16.3cm x 16 cm)
Weight
NX Solo: 5.1 lbs (2.3 Kg)
NX Pro: 6.6 lbs (3 Kg)
NX Pro+ Expansion Unit: 8 lbs (3.6 Kg)
Test Point Interface
64 pin card edge connectors (or equivalent)
Discrete Wire: AMP# 2-583718-7
Ribbon Cable: 3M# 3403-0001
Operating Temperature
40 – 100 degrees F (4 - 38 degrees Celsius)
PROGRAMMING
Program Generation
The NX Editor software program is used to generate test programs for
all NX Testers. The NX Editor is compatible with Windows 2000 and
Window XP operation systems.
Program Loading
Programs may be transferred to the NX Tester from the PC using the
NX Memory Card and the Memory Card Reader/Writer.
Alternatively, programs may be downloaded from the PC to the NX
Tester using an RS-232 serial port.