25
Dymax Edge-Carry Conveyor User Guide
Operating Instructions for Conveyors Using Fusion Lamp Systems
1.
Install all safety accessories to protect operator from UV light emissions.
2.
Apply power to the Conveyor and turn it on.
3.
Using the Speed Control Knob, unlock the Knob and adjust the speed for the desired setting. The Speed
Control Knob is a 10-turn Potentiometer and allows speed adjustment from approximately 0.8 FPM to 32
FPM (feet per minute).
Figure 59. Speed Control
Knob
Figure 60. Front Control Panel with Belt Speed Indicator
Display
4.
If any adjustments are needed for the Chain position or tension, refer to the Maintenance Section.
5.
Adjust the height of the Lamps to the desired distance.
6.
Once all the settings (speed and lamp height) have been properly set, the Conveyor is ready for
operation.
7.
Plug in the Conveyor and turn it on. When the Conveyor is operating, and the Chain is in motion, turn
the Power Supply on by
closing the Breaker(s) on both of the Power Supply’s Front Panels (
8.
Turn the Irradiators on by pressing the “Lamp On” Button (
Figure 62) of the Master Power Supply. Both
the Master and the Slave Power Supplies will go through a warm-up cycle. The Blower inside the
Irradiators will turn on and the Lamps will ignite. The Lamps reach full intensity within five seconds after
ignition. Your UVCS-F Conveyor is now ready for operation.
Figure 61. Breakers
Figure 62. Lamp Control Buttons
NOTE:
The Fusion Power Supplies are interlocked with the Conveyor so that the Conveyor must be
operating and the Conveyor Chain in motion before the Lamps will ignite.