Dymax Edge-Carry Conveyor User Guide
Specifications
General
For Systems Using Dymax EC-Series Flood Lamps
▪
A solid-state lamp power supply that allows external electrical inputs and provides power to the lamp
located in the lamp/reflector assembly housing. The power supply contains the on/off power switch and
hour meter that are located on the left side of the front panel. The power supply also houses its own
cooling fans and power distribution for optional accessories. The rear panel has an integrally fused AC
Power Receptacle, and a 14-pin female amp connector.
▪
The solid-state lamp power supply yields reliable and stabilized lamp voltage in virtually any electrical
system in the world. No other adjustment or settings are required other than ensuring a properly wire
configured plug is employed to the system. The power supply also conditions the electrical power to the
lamp providing longer, more reliable lamp life.
▪
A lamp/reflector assembly housing (refer to drawing on specific models) which contains the reflector, UV
lamp, lamp bases, high-voltage starter, and one circular connector.
▪
Connection cable between the power supply and lamp/reflector assembly housing.
▪
A power cord.
▪
400 Watt metal halide UV lamp, optional mercury vapor (PN 36970), or visible-spectrum lamps
(PN 36658) are available upon request.
For Systems Using Fusion Lamps
▪
A transformer-based lamp power supply that allows external electrical inputs and provides power to the
microwave lamp located in the reflector assembly housing. The power supply contains the on/off power
switch, control, and interlock circuitry. The power supply also houses its own cooling fans. The rear panel
has an AC power receptacle and connections for the lamp, conveyor interlocks, and slave unit control.
▪
The lamp power supply allows adjustment for different voltage and frequency conditions suitable for
virtually any electrical system in the world. Switching between 50 and 60 HZ frequency operation requires
movement of capacitor jumpers in the power supplies. See the fusion lamp technical manual for specific
instructions.
▪
A power cord.
▪
Fusion “D”
lamp
s (PN 36399) are standard. “H”
lamp
s (PN 36441) and “V”
lamps (PN 38146) are available
upon request.