BlueWave® MX-Series 1 Channel Curing Systems User Guide
34
2.
Lay the emitter on its side with the cover facing upwards. Using a 5/64” hex key,
loosen and fully remove the two screws (Figure 24).
3.
Remove the side cover by lifting from the bottom as shown in Figure 25.
Figure 24. Remove Screws
Figure 25. Remove Side Cover
4.
Slide the damaged glass cover out (Figure 26), taking care not to touch the metallic
reflector surfaces
.
NOTE: If the old window has shattered, be sure to remove all debris before
attempting to install the new glass window.
5.
Unwrap the new window and carefully clean with the enclosed alcohol swab.
Holding the window by its sides, slide into the groove (Figure 27). Take care not to
touch the glass with bare hands, as any residue left on the window can adversely
affect the performance of the unit.
Figure 26. Slide Glass Cover Out
Figure 27. Insert New Glass
Cover
6.
Reinstall the side cover removed in Step 3.
7.
Insert the two screws removed in Step 2 and tighten.