BlueWave® MX-Series 1 Channel Curing Systems User Guide
22
NOTE: When you initiate PLC mode you have the option to toggle PROG/ANALOG. PROG
will use the program that has been selected via the GUI. When you toggle back to
ANALOG mode you can then set the intensity via the analog intensity inputs (1VDC = 10%
intensity, 7VDC = 70%, etc) and then you can have your PLC outputs manage the
exposure time by asserting the LED ON command. This would essentially give you
controls to go to one preset program in PROG mode and then back to an analog control
that can be set to whatever your PLC dictates at that time.
Table 2. PLC Outputs & PLC Analog In
Signal Name / Description
Iso
lated In
p
u
ts
/
o
u
tp
u
ts
C
o
n
n
e
cto
r-
Pi
n
Signal Level
Si
gn
al
G
N
D
A
cti
ve
In
ac
ti
ve
PLC OUTPUTS
SYSTEM STATUS
Active
: Indicates the system is healthy.
Inactive
: Indicates that the system has one or
more operational problems.
OUT
1
2
0
VDC
24
VDC
LED STATUS
Indicates LED is commanded on. The LED "On"
status will stay in OFF state when in error
condition.
OUT
3
4
0
VDC
24
VDC
RESERVED
No Connection
5
6
PLC ANALOG IN
ANALOG INTENSITY
Analog signal applied to this input to control
the LED intensity.
IN
1
2
0 to 10 VDC