NT11 BOARD
SETTINGS AND FUNCTIONS
Blue - Rate Of Fire (ROF)
Values 1 - 45 (factory default 12.5 bps)
The ROF setting is used to set the maximum rate of fire of the NT11.
The values do not correspond directly to a certain Balls
Per Second (BPS).
The factory setting is
20
(
12.5 bps
).
Yellow - Firing Mode
Values 1 - 4 (default 1)
This setting changes the firing mode of the NT11. Default is
semiautomatic. In the semiautomatic mode, one trigger pull
shoots out one paintball. The PSP mode and the Millennium
mode follow the rules of the paintball tournament series.
Value 1
-
Semiautomatic Mode
Value 2
-
Millennium Mode
Value 3
-
PSP Mode
Value 4
-
NXL Mode, Full auto after 3rd shot.
1
9.80 BPS
2
9.90 BPS
3
10.0 BPS
4
10.10 BPS
5
10.20 BPS
6
10.30 BPS
7
10.41 BPS
8
10.52 BPS
9
10.63 BPS
10
10.75 BPS
11
10.86 BPS
12
10.98 BPS
13
11.11 BPS
14
11.62 BPS
15
11.76 BPS
16
11.90 BPS
17
12.04 BPS
18
12.19 BPS
19
12.34 BPS
20
12.50
BPS
21
12.65 BPS
22
12.82 BPS
23
12.98 BPS
24
13.15 BPS
25
13.33 BPS
26
13.51 BPS
27
13.69 BPS
28
13.88 BPS
29
14.08 BPS
30
14.28 BPS
31
14.49 BPS
32
14.70 BPS
33
14.92 BPS
34
15.15 BPS
35
15.38 BPS
36
15.62 BPS
37
15.87 BPS
38
16.12 BPS
39
16.39 BPS
40
16.66 BPS
41
20.0 BPS
42
22.22 BPS
43
25.0 BPS
44
28.57 BPS
45
33.33 BPS
NT11 BOARD
SETTINGS AND FUNCTIONS
Configuration Mode
-
The following settings can only be modified
in configuration mode and if dip switch 1 is in the ON (up)
position. To activate configuration mode, turn your marker off and
set DIP switch 2 to the ON position. Next, turn your marker on.
The LEDs cycle through all colors for one second to indicate
that you have entered the configuration mode.
To cycle through different settings, pull and release the trigger. Configuration mode has 4 set-
tings that can be changed.
Green - Trigger Sensitivity
Red - Dwell
NORMAL
MODE
CONFIGURATION
MODE
W W W . D Y E P A I N T B A L L . C O M
W W W . D Y E P A I N T B A L L . C O M
10
11
Values 1 - 20 (factory default 3)
Trigger sensitivity is the amount of time that the trigger has to be released
before the next trigger pull is allowed. In some situations with too low of a
value, the NT11 can register more trigger pulls than what was actually pulled.
This can cause the NT11 to shoot full auto, even in semi-automatic mode. To fix
this, adjust trigger sensitivity setting higher.
Values 1 - 20 (factory default 9)
Dwell is the amount of time that the solenoid will be activated during each shot.
• It is not recommended to adjust the Dwell.
• If you choose to adjust the Dwell and use too low of setting the NT11
will not cycle.
• If you choose to adjust the Dwell and use too high of setting the NT11 will
begin to double fire.
Содержание NT11
Страница 1: ... ...