5-13
SpycerBox Ultra/Flex | Hardware Guide | Version 3.1
Rohde & Schwarz DVS GmbH
Maintenance
Controller Maintenance
5.
Remove the defective controller from the system and in its place
install a new one.
6.
Connect the cables to the controller again in the same manner as
they were on the old controller.
7.
Next close the casing of the system as described in section “Clos-
ing the Casing” on page 5-9.
With the last step finished you have successfully replaced the defective
RAID controller. Now, you have to integrate the new controller in the ex-
isting configuration:
8.
Turn on the system as described in section “Starting the System”
on page 4-2.
After the initial booting you will see an output that is similar to the fol-
lowing lines:
Following foreign Arrays are found:
<Array>
Press <Enter> to accept the current configuration
Press <Ctrl-A> to enter Adaptec RAID Configuration
Utility
Press <Ctrl-H> to Pause Configuration Messages
(Default i s not to accept if no valid key pressed in 30
seconds)
9.
Press [Enter] on the keyboard to accept the configuration
detected by the system.
After this the newly installed RAID controller automatically initiates a
verify of the connected hard disks which may take some time. When
finished, the system will continue its booting procedure until the oper-
ating system is fully loaded. You may then continue your work with the
system.
System damage
Others than the original manufacturer spare parts might damage
your system.
Only use original manufacturer spare parts.
System failure
The wrong controller firmware might lead to incompatibilities and
malfunctions of the system.
The new controller must have the same firmware installed
as the other controllers.
Depending on the system you have purchased, you may see different
lines on the screen and you may have to press e.g. [F] on the
SpycerBox Ultra to accept the configuration.
Содержание SpycerBox Flex
Страница 1: ...SpycerBox Ultra Flex Hardware Guide Version 3 1 Storage Solution SpycerBox Ultra Flex Hardware Guide...
Страница 2: ...SpycerBox Ultra Flex Hardware Guide Version 3 1 Rohde Schwarz DVS GmbH...
Страница 6: ...SpycerBox Ultra Flex Hardware Guide Version 3 1 Rohde Schwarz DVS GmbH...
Страница 18: ...Introduction Important Notes 1 10 SpycerBox Ultra Flex Hardware Guide Version 3 1 Rohde Schwarz DVS GmbH...
Страница 38: ...Overview Battery Backup Unit 2 20 SpycerBox Ultra Flex Hardware Guide Version 3 1 Rohde Schwarz DVS GmbH...
Страница 80: ...Appendix Conformity Declarations A 12 SpycerBox Ultra Flex Hardware Guide Version 3 1 Rohde Schwarz DVS GmbH...
Страница 84: ...Index I 4 SpycerBox Ultra Flex Hardware Guide Version 3 1 Rohde Schwarz DVS GmbH...