19
11. Electronic Card Alarms
Electronic card alarms list :
•
Brush motor or Suction motor overload , electronic card stops the function and the LED (ref 4 or 5 )
blink slowly. To reset turn OFF and ON machine with ref 3.
•
Brush motor or Suction motor power card circuit over-temperature, card stops the function and the
LED (ref 4 or 5) blink quickly. To reset turn OFF and ON machine with ref 3.
•
Brush motor short circuit, electronic card stops the function and LED ref 4 blinks twice
•
Brush motor over-temperature, electronic card stops the function until motor cools down and the
thermal sensor closes the circuit again.