Setting the needle bar
Service Instructions 878-M PREMIUM - 03.0 - 10/2019
29
7.2
Angular position of the single-needle sewing machine
needle holder
Proper setting
The angular position of the needle holder should be set depending on the
needle number as per the table:
Fig. 18: Angular position of the single-needle sewing machine needle holder
1.
Remove the head cover (
2.
Loosen the screw (2) and turn the needle bar so that the right end of
the groove (1) faces the needle bar axis.
3.
Tighten the screw (2).
4.
Lock the machine in place at position
2
5.
Insert the 2.5 mm Allen wrench into the opening (4) and loosen the
fixing screw of the needle holder inside the needle bar.
6.
Turn the needle holder (3) to have the correct setting.
7.
Tighten the fixing screw.
Needle holder displacement
Needle number
70 – 110
120 – 160
180 – 200
(1)
- Groove
(2)
- Screw
(3)
- Needle holder
(4)
- Opening
(5)
- 2.5 mm Alley wrench
⑤
④
②
③
①
Содержание 878-M PREMIUM
Страница 1: ...878 M PREMIUM Service Instructions...
Страница 10: ...About these instructions 8 Service Instructions 878 M PREMIUM 03 0 10 2019...
Страница 66: ...Integrated motor 64 Service Instructions 878 M PREMIUM 03 0 10 2019...
Страница 114: ...Maintenance 112 Service Instructions 878 M PREMIUM 03 0 10 2019...
Страница 116: ...Decommissioning 114 Service Instructions 878 M PREMIUM 03 0 10 2019...
Страница 118: ...Disposal 116 Service Instructions 878 M PREMIUM 03 0 10 2019...
Страница 126: ...Technical data 124 Service Instructions 878 M PREMIUM 03 0 10 2019...
Страница 127: ...Appendix Service Instructions 878 M PREMIUM 03 0 10 2019 125 23 Appendix Wiring diagram...
Страница 128: ...Appendix 126 Service Instructions 878 M PREMIUM 03 0 10 2019...
Страница 129: ......