Mastergenerator ModBus Functions
2004 Carlo Gavazzi Industri A/S. All rights reserved.
107
Dec
Hex
Mux
Hi
Lo
Value
784
310
0
HI
LO
CD-0
Input Table
785
311
1
HI
LO
CD-1
Input Table
786
312
2
HI
LO
CD-2
Input Table
787
313
3
HI
LO
CD-3
Input Table
-
-
-
-
-
-
Input Table
799
31F
F
HI
LO
CD-F
Input Table
800
320
0
H!
LO
EF-0
Input Table
815
32F
F
HI
LO
EF-F
Input Table
816
320
0
HI
LO
GH-0
Input Table
831
33F
F
HI
LO
GH-F
Input Table
832
340
0
HI
LO
IJ-0
Input Table
847
34F
F
HI
LO
IJ-F
Input Table
848
350
0
HI
LO
KL-0
Input Table
863
35F
F
HI
LO
KL-F
Input Table
864
360
0
HI
LO
MN-0
Input Table
879
36F
F
HI
LO
MN-F
Input Table
880
370
0
HI
LO
OP-0
Input Table
895
37F
F
HI
LO
OP-15
Input Table
4096
1000
B8-B1
A8-A1
Digital
4097
1001
D
C
Digital
.
.
Digital
4103
1007
P
O
Digital
4112
1010
B8-B1
A8-A1
Digital
4113
1011
D
C
Digital
Digital
4119
1007
P
O
Digital
4880
1310
0
HI
LO
CD-0
Input Table
4881
1311
1
HI
LO
CD-1
Input Table
4882
1312
2
HI
LO
CD-2
Input Table
4883
1313
3
HI
LO
CD-3
Input Table
-
.
-
-
-
-
Input Table
4895
131F
F
HI
LO
CD-F
Input Table
4896
1320
0
H!
LO
EF-0
Input Table
4911
132F
F
HI
LO
EF-F
Input Table
4912
1330
0
HI
LO
GH-0
Input Table
4929
133F
F
HI
LO
GH-F
Input Table
4930
1340
0
HI
LO
IJ-0
Input Table
4943
134F
F
HI
LO
IJ-F
Input Table
4944
1350
0
HI
LO
KL-0
Input Table
4959
135F
F
HI
LO
KL-F
Input Table
4960
1360
0
HI
LO
MN-0
Input Table
4975
136F
F
HI
LO
MN-F
Input Table
4976
1370
0
HI
LO
OP-0
Input Table
4990
137F
F
HI
LO
OP-15
Input Table
8192
2000
HI
LO
Substatations
1..16
Status
8193
2001
HI
LO
Substations 17..32
Status
8194
2002
HI
LO
Substations 1.. 16
Status
8195
2003
HI
LO
Substations 17..32
Status
Dec
Hex
Hi
Lo
8208
2010
Hour
Minute
0..23
0..59
Setup
8209
2011
Second
s
Day of
week
0..59
0..FF
Setup
8210
2012
Month
Date
1..12
1..31
Setup
8211
2013
Year
Year
0..99
0..99
Setup
Multiplexed analog Read Input Table
Registers 0300H to 037FH BCD-VALUES
Resisters 0400H to 047FH BINARY-VALUES
Multiplexed analog values only valid if Multiplexer is selected
Reading of 1 to 32 registers possible
Dupline group AB holds the actual Mux-address on the 4 most significant bits.
The remaining bits holds the digital transmit information from channel A5..B8
Active Devices found in the RS485 Network
32 bits indicating the presence of slaves in the Network
Register 2002h, MSB = Slave no 00 (central=0). LSB = Slave no 15
Register 2003h, MSB = Slave no 16 LSB = Slave no31.
2 Registers.
Reads information previously written by a Modbus command for transmission on
Dupline
Reading of 1 to 8 registers possible.
If an attempt is made to read from a start-address and the number of registers exceeds
the allowed register range, no answer will be made, as this is interpreted as an illegal
function
Reads information previously written by a Modbus command for forced output on
Dupline.
Reading of 1 to 8 registers possible.
If an attempt is made to read from a start-address and the number of registers exceeds
the allowed register range, no answer will be made, as this is interpreted as an illegal
function
Multiplexed Analog Read Output Table
Registers 1300H to 137FH BCD-VALUES
Resisters 1400H to 147FH BINARY-VALUES
Multiplexed analog values only valid if Multiplexer is selected
Reading of 1 to 32 registers possible
In the Binary Data-area, the transmitted data are checked against valid BCD coding and also the control-
bits from the Analog transmitter.
Reading an “FFFF” indicates an invalid value or a non-existing analog transmitter.
Eg. Reading BCD data on Group C, then the channels C1 and C2 has to be active, before a binary value
are read. This is done automatically by the analog transmitters.
Active Devices found in Radio-Modem Network.
(When configured as Radio-modem Central)
32 bits indicating the presence of a Radio-Modem sbustation.
Register 2000h, MSB = Substation no 00 (central=0). LSB = Substation no 15
Register 2001h, MSB = Substation no 16 LSB = Substation no31.
2 Registers.
Read Generators internal 24 Hour clock.
Format: hh.mm, ss,dd,MM,DD,YYYY
Day of week: 1 Monday ..7 Sunday.
The Data format is BCD
Note: All 4 Registers must be read simultaneously.