APT3700N Smart Pressure Transmitter for Nuclear Service Operation Manual M3700N-K01E
30
content
indication
Description
Greatest Value
Shown
note
AUTO
shows the number automatically Decimal
is established (same as the original way)
99999
5-0
Decimal does not show the decimal place.
99999
4-1
Decimal shows the first decimal place
9999.9
3-2
Decimal shows the second decimal place
999.99
2-3
Decimal shows the third decimal place
99.999
1-4
Decimal shows the fourth decimal place
9.9999
- The first line of LCD is expressed in the selection way of
0.0
.
- Everytime time pressing the Zero button shows a display system of selecting a display
system of span button of saving a setting value
- The set Decimal Place content is PV value and is valid in the engineering value, mA and %
is irrespectively a setting area not in 3-2's format.
- While operating the LCD, the greatest value shown of the second LCD
line shows a
LCD_OV
message and rotates the current setting of the Unit text.