When installing the nuclear power plant, the pipeline connecting and supplying is
through a Buyer.
2.4. Electric Consideration
The following page describes the electric transmitter's connection.
The worker should acknowledge the area of the transmitter when installing.
Duon System Co., LTD Model is a machine that uses the DC power to signal 4~20mA
dc of the 2 Wire way of fluctuating load.
The power should function at least at 12Vdc@ No-load(ZERO ohm), and a max of
21.1mA.
The transmitter's electric connection should refer to [Figure 3. transmitter's own
purchase material].
The transmitter's output range is shown as followed
.
The following voltage change can be shown the transmitter's output of the
impressed voltage.
: The input of power supply of
transmitter voltage
: Impressed Voltage
: Voltage Loss