3
(C)
DIMENSIONS
FIGURE 1-1 Dimensions
(D)
Wall Hanging
Bracket
(D)
(A)
(E)
Vent Connector
Combustion Air
Safety Relief
Valve
Connection
(¾ NPT)
(B)
Condensate Drain Connection (L)
Return Water (F)
Supply Water (F)
Gas Connection (K)
(G)
(J)
Table 1 : Physical Data
Models
050/075/100
150/200
299
Width (A)
20" (508mm)
23" (584mm)
Height (B)
30" (762mm)
40" (1041mm)
Depth (C)
14" (356mm)
16.0"
(406mm)
18.3"
(465mm)
Bracket (D)
28" (711mm)
40" (1016mm)
Height (E)
31" (787mm)
42" (1092mm)
Water
Connections
Size(F)
1-1/4" NPT
1-1/4" NPT
Location (G)
2" (51mm)
2" (51mm)
Location (H)
5" (127mm)
2" (51mm)
Location (I)
3" (76mm)
4-
½
" (114mm)
Gas
Connection
Location (J)
4-1/2" (114mm)
4-1/2" (114mm)
Size (K)
1/2"
NPT
3/4"
NPT
Condensate Drain
Connection (L)
3/4" NPT
3/4" NPT
Weight
Shipping
111 lb (50 kg)
~
182 lb
(83 kg)
~
225 lb
(102 kg)
Unit
91 lb (41 kg)
~
157 lb
(71 kg)
~
195 lb
(89 kg)
Vent Connector
2" (51mm)
3" (76mm)
(H)
(I)
DIMENSIONS
Содержание DKVLT-050
Страница 47: ...47 13 TROUBLE SHOOTING ...
Страница 51: ...51 13 TROUBLE SHOOTING ...
Страница 53: ...53 13 TROUBLE SHOOTING ...
Страница 62: ...62 Supply Water Temperature Sensor Resistance Chart 13 TROUBLE SHOOTING ...
Страница 64: ...64 14 WIRING DIAGRAM 14 1 Connection Diagram 050 075 100 150 200 MBH ...
Страница 66: ...66 14 WIRING DIAGRAM 14 3 Connection Diagram 299 MBH EXTERNAL PUMP RELAY LIMIT OF 1 AMP PER PUMP SEE SECTION 8 ...
Страница 83: ...83 NOTES ...
Страница 84: ...ECR International Inc 2201 Dwyer Avenue Utica NY 13501 web site www ecrinternational com ...