Infinity™
Series Servo Ultrasonic Press Systems QUICK START GUIDE
12
SE
CTION 3
| I
NST
ALLA
TION
AC Power Requirements
The AC line voltage and current needed depends on which generator and press has been chosen for the system. See Tables 3-1
and 3-2.
Generators
TABLE 3-I NOTES:
1.
Maximum line current requirement is specified at the minimum nominal AC line voltage and the rated power level.
2.
For the 2600 watt model, if the input line voltage is between 180-190V, the output is reduced to 2400 watts.
3.
For 380-480 VAC generators, the ex24V power supply that is connected to the +24V generator input shall be listed or
labeled with 3rd party North America marking (UL, CSA, TUV, etc).
Table 3-1
Generator AC Power requirements
Table 3-2
Press AC Power requirements
Operating
Frequency
Generator Model
Number
Overload
Power
Ratings
(Watts)
Input AC Power Requirements
Nominal AC Volt at Maximum
RMS Current
North America/
Japan AC Outlet
Rating
Output
Voltage
(Nominal)
Output
Current
(Max)
15kHz
15HS360-2y-C0-S-N0
3600
200-240V 50/60 Hz @ 19 Amps
20A or 30A
1100
3.6
15kHz
15HS500-2y-C0-S-N0
5000
200-240V 50/60 Hz @ 26 Amps
30A
1100
5.0
15kHz
15HS360-4y-C0-S-N0
3600
380-480V 50/60 Hz @ 8 Amps
20A or 30A (3 Phase)
1100
3.6
15kHz
15HS500-4y-C0-S-N0
5000
380-480V 50/60 Hz @ 10 Amps
20A or 30A (3 Phase)
1100
5.0
20kHz
20HS120-Uy-C0-S-N0
1200
100-240V 50/60 Hz @ 15 Amp
15A
1300
1.0
20kHz
20HS180-2y-C0-S-N0
1800
200-240V 50/60 Hz @ 10 Amps
15A
1300
1.5
20kHz
20HS260-2y-C0-S-N0
2600
200-240V 50/60 Hz @ 15 Amps
15A
1300
2.2
20kHz
20HS360-2y-C0-S-N0
3600
200-240V 50/60 Hz @ 19 Amps
20A or 30A
1300
3.0
20kHz
20HS500-2y-C0-S-N0
5000
200-240V 50/60 Hz @ 26 Amps
30A
1100
5.0
20kHz
20HS360-4y-C0-S-N0
3600
380-480V 50/60 Hz @ 8 Amps
20A or 30A (3 Phase)
1300
3.0
20kHz
20HS500-4y-C0-S-N0
5000
380-480V 50/60 Hz @ 10 Amps
20A or 30A (3 Phase)
1100
5.0
25kHz
25HS120-UP-C0-S-N0
1200
100-240V 50/60 Hz @ 15 Amps
15A
1000
1.3
25kHz
25HS200-2P-C0-S-N0
2000
200-240V 50/60 Hz @ 11 Amps
15A
1000
2.2
30kHz
30HS120-UP-C0-S-N0
1200
100-240V 50/60 Hz @ 15 Amps
15A
850
1.6
30kHz
30HS180-2P-C0-S-N0
1800
200-240V 50/60 Hz @ 10 Amps
15A
850
2.3
35kHz
35HS120-UP-C0-S-N0
1200
100-240V 50/60 Hz @ 15 Amps
15A
850
1.6
40kHz
40HS120-UP-C0-S-N0
1200
100-240V 50/60 Hz @ 15 Amps
15A
750
1.8
50kHz
50HS060-UP-C0-S-N0
600
100-240V 50/60 Hz @ 8 Amps
15A
850
0.8
Model Number
Input AC Power Requirements Nominal AC Voltage
@ Maximum RMS Current
North America/ Japan
AC Outlet Rating
43NSLA
90-240V 50/60 Hz @ 15 Amps
15 Amps
43NSME
90-240V 50/60 Hz @ 10 Amps
15 Amps
Presses
Dukane HMI
AC line voltage - 90-260 VAC
AC line current - 1 Amp