Installing the Ultrasonic Stack Module
For model 43NTME (20 kHz):
If the ultrasonic stack module is not installed in the press, follow the instructions below, depending on the model.
1.
Activate the E-STOP (Abort) switch on the front of the press base shown in Fig. 4-2 below.
2.
Turn off power to the generator by placing the AC switch in the “0” position.
3.
Push the button on the bottom of the transducer door as shown in Fig. 4-3 by the arrow labeled 1. The door latch
should release.
4.
Grip the transducer door on both sides and pull down and out as shown in Fig. 4-3 by arrows 2 and 3. Set the
door aside.
Figure 4-2
E-Stop Button (Abort)
Figure 4-3
Door release Button