SE
CTION 4
| C
ONTR
OLS
AND
I
NDICA
TORS
Infinity™
Series Servo Ultrasonic Press Systems QUICK START GUIDE
23
5.
remove the 6 mm hex wrench, Dukane part number 809-721-0013, stored on the inside of the door as show in Fig
4-15, then set the door aside.
6.
Use the wrench to loosen the (2) screws shown in Fig 4-16.
7.
Pull the transducer clamp bar straight out as shown in Fig 4-17 by arrow 1, then rotate it 180 degrees counter-
clockwise and push it back in as shown by arrows 2 and 3. The clamp should rest as shown in Fig 4-18.
Figure 4-15
Hex Wrench Location
Figure 4-17
Transducer Clamp Bar
Figure 4-16
Transducer Clamp Bar Screws
Figure 4-18
Clamp Bar resting Position