SE
CTION 4
| C
ONTR
OLS
AND
I
NDICA
TORS
Infinity™
Series Servo Ultrasonic Press Systems QUICK START GUIDE
25
Removing the Ultrasonic Stack Module
For model 43NTME (20 kHz):
Perform the following steps, depending on the model. The first two steps are necessary to ensure that no
power will be accidentally applied while removing the stack.
1.
Activate the E-STOP (Abort) switch on the front of the press base shown in Fig. 4-25.
2.
Power down the generator by placing the AC switch in the “0” position.
3.
Push the button on the bottom of the transducer door as shown in Fig. 4-26 by the arrow labeled 1. The door latch
should release.
4.
Grip the transducer door on both sides and pull down and out as shown in Fig. 4-26 by arrows 2 and 3.
5.
Unlock the handle as shown in Fig. 4-27, on the next page, by rotating it until it stops.
6.
Pull the handle shown in Fig. 4-28 to rotate the transducer clamp until it stops.
7.
rotate the two handles that secure the stack in place, one at a time, as shown in Fig. 4-29 until the handle threads
disengage from the press (approximately 7 turns).
8.
Pull the stack out of the press using the fixed handle as show in Fig. 4-30.
Figure 4-25
E-Stop Button (Abort)
Figure 4-26
Door release Button