background image

DTI GmbH & Co. KG 

 

Manual  

and 

Handbook 

 

DTI-Puls 

 
 
 
 
 

 

 

 
 
 

Seite 1 von 31 

Содержание DTI-Puls-Series

Страница 1: ...DTI GmbH Co KG Manual and Handbook DTI Puls Seite 1 von 31...

Страница 2: ...erent kind of ways The software may be adapted according the newest versions The hardware does have several plugs f r future expandations The detector can follow technonogical improvements for a longe...

Страница 3: ...DTI GmbH Co KG Lieferung in stabiler Alu Box Seite 3 von 31...

Страница 4: ...coil you will find the headphone and the battery charger Furthermore you will see the charging regula tor a cable and rods for the coil Mount the coil to the lower rod Assamble the rods and adjust th...

Страница 5: ...DTI GmbH Co KG Funktion Connecting Touchkeys F1 F4 Touchkey F5 Back to Graphic Display Load On Off Switch Headphone Connector for coil Communication Connector for PC Seite 5 von 31...

Страница 6: ...detector has connectors on both sides Below the ON OFF switch is the coil connector It has a protecting cap prohibiting coming dirt and moisture in it Please put this cap always on if you don t use th...

Страница 7: ...The exeption is when you will be asked for by the menue See the chapter Changing Coils Look for a place where are not many big metal parts near by In rooms television or computers may not be switched...

Страница 8: ...DTI GmbH Co KG If there is no problem with the rechargeable battery you will see the start logo To gether with the start logo the detector starts sending pulses The start phases starts Seite 8 von 31...

Страница 9: ...he detector is waiting for ist starting require ments You have three possibiities for starting F1 Normal start with coil You press F1 F2 Start in demonstration mode No coil is neccessary F3 Reset Set...

Страница 10: ...set Coil neccessary System has been startet without coil Please switch off When you choose a start with coil without having connected a coil this message will be displayed The system switches to the d...

Страница 11: ...is displayed by a bargraph On the left of the display you will see the spectrum of measured signal With help of the spectrum on basis of 9 spec tral lines you are able to do an additionally analysis B...

Страница 12: ...ed object may be Generally a click rate of 1 2 will be adjusted without signal You press F1 and as an active parameter you will see Suchspeicher Searching Memory The main memory of the system has been...

Страница 13: ...aracteristics of the metals Deciding are its conductivity shape alloy position and distance Furthermore die type of soil is important The electromagnetic field may be influenced Also there is an enorm...

Страница 14: ...sitiv parameter and should only be used for very low signals When the audio amplifier is set to maximum and the searching sensitivity will be rised the searching amplifier will be multiplied by the au...

Страница 15: ...parameter By the pushbutton F1 F2 you change the value By the pushbutton F3 you save the setting If you have chosen to change the parameter by F3 you need to save by F3 because otherwise you are not...

Страница 16: ...ws a wireless transmittion to a wireless headphone The autio transmitter can be put in addi tionall It always comes together with the GENESIS 4 Tondiskriminator Tone Discriminator By ton discriminator...

Страница 17: ...l the display to the tone behaviour 3 Skala Grafik Scale Graphic This parameter changes the display range of detection record 4 Skala Spektrum Scale Spectrum This parameter changes the display range o...

Страница 18: ...be stored If you leave the menue by F4 or F5 you will receive a message You will now be able to change the coil when the detector is switched on Only if you see this message changing is allowed After...

Страница 19: ...ntical to the active parameter and can be changed here 5 Below this parameter you can change the puls power 6 This paramter is identical to the active parameter and can be changed here 7 This paramter...

Страница 20: ...values of the program Here as an example Program 1 without stored values As discribed the searching memory is always 11 By the pushbutton F1 F2 you can choose the program By the pushbutton F5 you leav...

Страница 21: ...lay The thermal starting phase begins A loaded rechargeable battery needs some minutes until it reaches to its actually voltage Also the electronic gets stabilized Press the pushbutton REF ERENZ refer...

Страница 22: ...by the object before you could hear a click This value now is the new threshold The response is increased now Test it with your test ob ject By the parameter TONGENERATOR Tone Generator you adjust the...

Страница 23: ...adjustment in the lower range will have following effects The Tongenerator tone generator doesn t work in the range minimum to maxi mum any more but reacts in the lower range or not at all The bargrap...

Страница 24: ...able to do this reference automatically because you might not notice it or the coil might not be in the correct position That could cause week signals being eliminated See REFERENZ Combine the test wi...

Страница 25: ...ame characteristic and can be filtered out in the same way When testing this parameters do as with the Suchspeicher searching memory The searching memory should always be set to 10 15 By this paramete...

Страница 26: ...eter Pulsleistung puls power has not been discussed In air an increase of the puls power can be recognized only at big objects The transmis sion field is not disturbed through its way through the air...

Страница 27: ...position depth and soil If you think about how many factors have to be considered it is not surprising Therefore test with different objects and necessary Bigger or massif precious metals will always...

Страница 28: ...bject until a detection can be recognized Now chose the Suchspeicher searching memory and decrease the value The detection signal now will become stronger without changing the dis tance Rise the coil...

Страница 29: ...le connector of the DC DC converter to the female connector of the detector Connect the input connector the DC DC converter to the car battery plug If there is battery power the LED s will be switched...

Страница 30: ...d also Repairing those failures will be charged In case of an unfounded warranty claim the demanding per son will be charged for all costs Precondition for fulfilling the warranty duty is the presenta...

Страница 31: ...Discriminator 13 Objektgr e Object Size 14 Suchempfindlichkeit Searching Sensitivity 14 Menue Options 15 Operating the Detector 21 Battery Charger 29 Warranty 30 Danger 30 C Copyright The copyright fo...

Отзывы: