Version 4/5/6/7
DTDAUTO VIETNAM Co., Ltd – EDITED 29/10/2020
www.dtdauto.com
81
The screen will show as below:
P/N: Serial number
M/C: Machine code
3. Contact with DTDAuto (
www.dtdauto.com
) to request update support.
Please send “
Serial number
” of MOTOSCAN and “
Your ID
”, “
Password
”
of Teamview to DTDAuto.
4. Do not use mouse and keyboard. Wait for DTDAuto technician to
perform. It will take about 15 to 30 minutes.
5. SOME REPORT MAY BE SHOW ON MOTOSCAN SCREEN
5.1 SOME ERRORS CONNECTING TO MOTORCYCLE
When the communication between MOTOSCAN and motorcycles is error
please follow the below steps:
- Confirm that ignition key is being ON position
- Check connection of wiring and diagnostic connector
(it is not loose or
error signal line from ECU to diagnostic connector).
-
Notes: diagnostic connectors on the Honda Motorcycles are red
color and near battery.
White connector is not use for MOTOSCAN, it is
only waiting connector use for development in the future
- Check position of optical sensor is on location of malfunction indicator
lamp
(check engine light)
.
- Check ECU supply power or check ECU
- Check the power supply for ECM or ECU has been faulty inside.
Version 4/5/6/7
DTDAUTO VIETNAM Co., Ltd – EDITED 29/10/2020
www.dtdauto.com
82
5.2 ERROR OPERATING
If MOTOSCAN work a long time but do not display message on screen,
follow the below steps to reset MOTOSCAN:
- Turn OFF the power of MOTOSCAN
- Turn OFF the Ignition switch on motorcycle on 5 seconds later
- Turn ON Ignition key back and manipulate from a first step
5.3 PROBLEM FROM OPERATE USER
- User must perform true following guide on screen of MOTOSCAN.
- MOTOSCAN will not work if you do wrong manipulations.
- Some case be wrong battery power cable, it maybe cause fires and short
connection cable, therefore:
+ Connecting MOTOSCAN to motorcycle in according to wiring connection
diagrams with each kind of motorcycles
(view it in user guide).
+ Do not use MT001-POWER cable if wiring connection diagram do not
require.
5.4 MOTOSCAN CAN NOT TURN ON POWER
- Check the connection of diagnostic connector and MOTOSCAN
(loose)
- Check supply voltage
(10VDC to 14VDC)
- Check pins of connector (damage, broken)
- Contact with to the phone number for the support: (+84)43.7845426