This equipment 3G4010 is fixed and shall be installed by Service Persons only (Service Person is 
defined as a person having the appropriate technical training and experience necessary to be 
aware of hazards to which that person may be exposed in performing a task, and of measures 
available to minimize the risks to that person or other persons). It shall be installed and used 
within an environment that provides the pollution degree max 2, over voltages category II, in 
non-hazardous, indoor locations only. This manual shall be used with the Installation Manual of 
the relevant alarm control panel. All instructions specified within that manual must be observed.

Description

This 3G4010 manages transmissions to a central station and can simulate the landline in the event of 
trouble (e.g., landline down) or even substitute the landline completely in areas where the 3G or 2G 
wireless service is provided and a landline is not available.
The 3G4010 has the capability of communicating alarm signals via the 3G or 2G data network. This 
capability ensures a fast, reliable path to central stations equipped with a Sur-Gard System I / II / III / IV 
receiver. By connecting a 3G4010 to a control panel's standard PSTN interface, telephone-based 
Contact ID signals are decoded and seamlessly routed through the 3G or 2G network to any of the 
compatible receiver options.
The performance of the 3G4010 depends greatly on wireless network coverage. Therefore, it should not 
be mounted without first performing placement tests to determine the best location for reception 
(minimum of one green LED ON). Optional antenna kits – GS15/25/50-ANT (15ft/4.6m, 25ft/7.6m or 
50ft/15.2m) – are available.

The 

3

G4010 requires enrollment with CONNECT 24 to operate. Dealer application forms and 

additional information on the CONNECT 24 Voice Response Unit (VRU) and web user interface can 
be found at www.connect24.com, or at the following telephone numbers:
USA 1-888-251-7458  CANADA 1-888-955-558

3

For UL Residential Fire and Burglary installations, the 3G4010 is listed as a sole means of communication 
or as a back up when used in conjunction with a POTS line (dialer). For UL Residential Fire installations, 
when installed in the alternate enclosure for 3G4010CF, the 3G4010 has provisions for 24-hour standby 
power.
For UL Commercial Burglary installations, the 3G4010 is listed as a  sole means of communication 
(supervision window of 200s required at monitoring station) or as a back-up when used in conjunction 
with a POTS line (dialer).
The 3G4010 shall be powered from any compatible listed control unit or compatible listed power supply that 
complies with the ratings specified on page 1. The power supply shall be listed for burglary applications and 
provide a minimum of 4 hours standby power capabilities. An example of a suitable listed compatible control 
unit is the DSC Model PC1864 with an AUX output rated 11.1 - 12.6VDC. An example of a suitable Listed 
power supply is DSC Model PC5204 with an AUX output rated 11.6 - 12.6VDC.
For ULC Commercial Fire Monitoring installations the 3G4010 is listed as a passive communication  
system when used in conjunction with a POTS line (dialer). Fire alarms shall be sent simultaneously over 
both communication methods (wireless network and PSTN).
For ULC Commercial Burglary installations the 3G4010 is listed as a passive communication system with 
communication line security level P2 when used as a back up in conjunction with a POTS line (dialer).
For ULC Residential Fire and Burglary installations the 3G4010 is listed as a sole means communication 
or as a back up when used in conjunction with a POTS line (dialer).

ATTENTION: 

The 3G4010 is equipped with a current limiter that limits current demand on the 

12V

DC

 power input to 120mA. The current limiter is enabled by default (see Part #8 in 'Identifica-

tion of Parts’ on page 3) with CON5 in the OFF position. The current limiter can be disabled 
(bypassed) with CON5 in the ON position. When the 3G4010 12V

DC

 power input is supplied by the 

Alarm Panel Aux+ output, DSC recommends that the current limiter be active to limit the demand 
from the panel. If the alarm panel is intended to supply all of the current demand, you must 
ensure that the panel can supply 500mA and that the current limiter is disabled. When the 3G4010 
is transmitting, the current demand exceeds 120mA (500mA). With the current limiter in place, 
the additional current demand is supplied by the 3G4010 battery.

NOTE: 

With the current limiter active, there is a risk of discharging the 3G4010 battery when 

transmission frequency is high. The back up battery must always be connected to the device when 
the current limiter is enabled.

If power to the 3G4010 is supplied by an external power supply (recommended 13.8 V

DC

, 0.7A), the 

current limiter must be disabled to allow the full current demand to be supplied. In this configuration 
the 3G4010 battery is not required.

Содержание 3G4010

Страница 1: ...CATOR INSTALLATION MANUAL V4 0 WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manu facturer The en...

Страница 2: ...10 4 Status LEDS 5 Operating Principles 6 Simulated Landline Mode 6 Panel Transmission Monitoring PTM 6 Wireless Communications Sequence 6 Inputs 6 Outputs 7 Activating the Outputs 7 Swinger Shutdown...

Страница 3: ...user to Not attempt to service this product Opening or removing covers may expose the user to dangerous voltages or other risks Any servicing shall be referred to trained service persons only Use aut...

Страница 4: ...upply rated for the application external power limited source NOTE The power supply must be Class 2 Power Limited For residential applications a suitable power adap tor is model DSC ADP1310 NAU for US...

Страница 5: ...ircuit boards Maintain at least 1 25 4mm separation A minimum 1 4 6 4mm of separation must be maintained at all points between Power Limited wiring and all other non Power Limited wiring Route wires a...

Страница 6: ...d as a sole means of communication supervision window of 200s required at monitoring station or as a back up when used in conjunction with a POTS line dialer The 3G4010 shall be powered from any compa...

Страница 7: ...OTE The green LEDs will indicate the signal strength The bottom green LED must be ON for the location to be acceptable Please refer to the Status LEDs section for more information 6 Power down the 3G4...

Страница 8: ...ED This LED is normally Off but it will flash in the event of a trouble This LED will switch on within three minutes in the event of wireless Module 16 trouble or when the wireless Network is unavaila...

Страница 9: ...ction sequence before switching The 3G4010 performs this sequence on any phone number that is detected on the line Specific central station phone numbers can be programmed into the 3G4010 if desired U...

Страница 10: ...he 3G4010 must be set as Active High NOTE Once an output has been activated automatically it will not restore its state until all the causes of activation are cleared Contact ID Events Description Eve...

Страница 11: ...panel or DC transformer to DC input backup battery if CON5 OFF Wiring Backup Incoming line to RING TIP on 3G4010 R 1 T 1 of 3G4010 to RING TIP of control panel R 1 T 1 of control panel to house phone...

Страница 12: ...means Trouble Status Trouble Status Troubleshooting Steps One Flash 3G4010 Low Battery Measure the battery under load and verify it is charged to at least 12 5 VDC If not wait at least 1 hour for the...

Страница 13: ...ion to verify that the 3G4010 programming is correct port IP address DNIS Contact your central station to verify they are not experiencing any receiver issues Seven Flashes DC Supply Trouble Ensure th...

Страница 14: ...control panel has the correct account num ber programmed Verify the reporting codes are programmed or the auto Contact ID option is enabled Ensure the control panel communicator is enabled Connect a h...

Страница 15: ...he lights will continue to flash in this sequence until the battery is charged above 12 4VDC Swinger Shutdown for Telephone Line Monitor TLM transmissions for backup units If the 3G4010 is configured...

Страница 16: ...ections are correct before turning on Connect relay contacts to a zone input on the alarm control panel for 3G4010 troubles supervision 24hr type zone Optional use of PGM output See Programming WARNIN...

Страница 17: ...tor NOTES 1 Program the Zone Point as Supervisory type with keypad only annunciation when in Alarm Do NOT use a point that is normally used for 2 Wire Smoke detectors 2 The power Supervision relay RM...

Страница 18: ...Control Unit Outputs Fire Supervisory Trouble DSC Subscribers Unit Fire Zone Inputs TIP TIP RING PGM1 DSC Keypad LCD4501 PK55XX 3G Wireless Transmitter 3G4010 T1 R1 TIP RING Zone Input PGM4 AUX Power...

Страница 19: ...TIP RING PGM1 DSC Keypad LCD4501 PK55XX 3G Wireless Transmitter 3G4010 T1 R1 PGM1 TIP RING Zone Input PGM4 AUX Power 12V 700mA RM1C ULC Relay PC5003C PC4050CR cabinet 3G HSPA 2G GPRS PSTN AC Input AC...

Страница 20: ...eless Network Supervision Relay Redundant Fire Alarm Transmission NOTE Use EOL resistor in series with N O contacts of the relay connected to PGM4 3 2 DC IN AUX 2 3 1 COM 4 1 COM T1 R1 TIP RING 4 PGM...

Страница 21: ...ork Supervision Relay Phone Line Supervision Relay and Redundant Fire Alarm Transmission NOTE Use EOL resistor in series with N O contacts of the relay connected to PGM4 5 6 KOhm 5 6 KOhm Wireless Net...

Страница 22: ...ees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights DSC ma...

Страница 23: ...AAAEQ TXXXX The digits represented by are the REN without a decimal point e g 03 is a REN of 0 3 For earlier products the REN is separately shown on the label Incidence of Harm If this equipment 3G401...

Страница 24: ...d damage from improper maintenance damage arising out of any other abuse mishandling or improper application of the products Items Not Covered by Warranty In addition to the items which void the Warra...

Отзывы: