Introduction

1

The 3G4010 is a wireless communicator that sends alarm system information to an Sur-Gard System I, II, 
III or IV receiver through a 3G (HSPA) or 2G (GPRS) wireless network. This wireless communicator can be 
used with UL/ULC Listed compatible control units, as indicated in the manufacturer's installation instruc-
tions.

NOTE: The 3G4010 is designed to work with SIA and the Contact ID communication format as described 
in SIA DC-05 Standard. Before completing the field installation of the alarm monitoring system please 
ensure communication with the supervising central station is successful by sending several events and 
getting confirmation that they have been received.

Features

• Compatible with 4-digit or 10-digit Contact ID communication format as described in SIA DC-05 

Standard. Example of suitable compatible alarm panels: DSC Models PC1864, PC1832, PC1616, 
PC4020.

• Simulates landline
• Switches automatically to the 3G (HSPA) or 2G (GPRS) network in the event of landline trouble 

(e.g., line down)

• Wireless Signal Indicator
• Four programmable outputs
• Contains one 12V - 1.2 Ah battery
• Case Tamper Output
• Landline overvoltage protection
• Tri-band UMTS/HSPA; Quad-Band GSM/EDGE Radio
• Four programmable inputs
• 3G (HSPA)/2G (GPRS) / Internet communication with Sur-Gard System I / II / III / IV
• Panel transmission monitoring for up to four phone numbers

Technical Specifications

The input voltage to the 3G4010 can be drawn from the UL/ULC Listed control panel or provided by an 
external UL/ULC Listed power supply rated for the application (external power-limited source).

NOTE

: The power supply must be Class 2, Power Limited. For residential applications a suitable power adap-

tor is model DSC ADP1310-NAU (for USA) and model DSC ADP1310-NA (for Canada).

Ratings

Power Supply Ratings -  Input Voltage (for long-term operation)

CON5-OFF with internal battery:  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   13.8V

DC

 required 

CON5-ON without internal battery:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   13.8V

DC

 recommended

NOTE: When the input voltage drops below 13.5V

DC

, the internal battery supplied with the 3G4010 

will not be charged. In order to maintain a charged level for the internal battery, the power supply 
must have a minimum voltage of 13.5V

DC

 to ensure a sufficient battery charge in all conditions of use.

Current Consumption

CON5-OFF with internal battery:  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  120mA*
CON5-ON without internal battery:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  500mA*

* Plus any current drawn from the 3G4010 AUX+ terminal

Working Voltage Range

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9-14V

DC

 

Battery:   .  .  .  .  .  .  .  .  .  .  .  .  .  sealed, rechargeable type, rated 12V/1.2Ah (for 24hr standby time)
Battery charging voltage: .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  13.5V

DC

Battery charging current: .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   50mA

NOTE: Battery must be replaced every 3-5 years.

Operating frequency:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  850/1900MHz
Antenna gain:  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   2.0dBi

Environmental Specifications

Operating temperature:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 0°C-49°C (32°F-120°F)
Humidity:   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .93%RH Maximum (non-condensing) 

Mechanical Specifications

Dimensions (metal enclosure, painted): .  .  .  .  .  .  .  .   138mm x 224mm x 55mm / 5.4” x 8.8” x 2.2”
Weight (without battery):   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  900g / 3.2oz
Internal Event Buffer (communications):  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   256 Events (not viewable)

Simulated Telco Loop specifications (TIP/RING)

On-Hook Voltage:  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 35V

DC

 

Loop Current .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   25mA
Loop Resistance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 600 Ohms 

Alternate construction 

Dimensions (enclosure for 3G4010CF):    .  .  .  .  .  .  .  . 165mm x 257mm x 76mm / 6.3” x 10.1” x 3”
Weight (alternate construction enclosure without battery):    .  .  .  .  .  .  .  .  .  .  .  .  .  .  1300g / 2.8lbs

Содержание 3G4010

Страница 1: ...CATOR INSTALLATION MANUAL V4 0 WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manu facturer The en...

Страница 2: ...10 4 Status LEDS 5 Operating Principles 6 Simulated Landline Mode 6 Panel Transmission Monitoring PTM 6 Wireless Communications Sequence 6 Inputs 6 Outputs 7 Activating the Outputs 7 Swinger Shutdown...

Страница 3: ...user to Not attempt to service this product Opening or removing covers may expose the user to dangerous voltages or other risks Any servicing shall be referred to trained service persons only Use aut...

Страница 4: ...upply rated for the application external power limited source NOTE The power supply must be Class 2 Power Limited For residential applications a suitable power adap tor is model DSC ADP1310 NAU for US...

Страница 5: ...ircuit boards Maintain at least 1 25 4mm separation A minimum 1 4 6 4mm of separation must be maintained at all points between Power Limited wiring and all other non Power Limited wiring Route wires a...

Страница 6: ...d as a sole means of communication supervision window of 200s required at monitoring station or as a back up when used in conjunction with a POTS line dialer The 3G4010 shall be powered from any compa...

Страница 7: ...OTE The green LEDs will indicate the signal strength The bottom green LED must be ON for the location to be acceptable Please refer to the Status LEDs section for more information 6 Power down the 3G4...

Страница 8: ...ED This LED is normally Off but it will flash in the event of a trouble This LED will switch on within three minutes in the event of wireless Module 16 trouble or when the wireless Network is unavaila...

Страница 9: ...ction sequence before switching The 3G4010 performs this sequence on any phone number that is detected on the line Specific central station phone numbers can be programmed into the 3G4010 if desired U...

Страница 10: ...he 3G4010 must be set as Active High NOTE Once an output has been activated automatically it will not restore its state until all the causes of activation are cleared Contact ID Events Description Eve...

Страница 11: ...panel or DC transformer to DC input backup battery if CON5 OFF Wiring Backup Incoming line to RING TIP on 3G4010 R 1 T 1 of 3G4010 to RING TIP of control panel R 1 T 1 of control panel to house phone...

Страница 12: ...means Trouble Status Trouble Status Troubleshooting Steps One Flash 3G4010 Low Battery Measure the battery under load and verify it is charged to at least 12 5 VDC If not wait at least 1 hour for the...

Страница 13: ...ion to verify that the 3G4010 programming is correct port IP address DNIS Contact your central station to verify they are not experiencing any receiver issues Seven Flashes DC Supply Trouble Ensure th...

Страница 14: ...control panel has the correct account num ber programmed Verify the reporting codes are programmed or the auto Contact ID option is enabled Ensure the control panel communicator is enabled Connect a h...

Страница 15: ...he lights will continue to flash in this sequence until the battery is charged above 12 4VDC Swinger Shutdown for Telephone Line Monitor TLM transmissions for backup units If the 3G4010 is configured...

Страница 16: ...ections are correct before turning on Connect relay contacts to a zone input on the alarm control panel for 3G4010 troubles supervision 24hr type zone Optional use of PGM output See Programming WARNIN...

Страница 17: ...tor NOTES 1 Program the Zone Point as Supervisory type with keypad only annunciation when in Alarm Do NOT use a point that is normally used for 2 Wire Smoke detectors 2 The power Supervision relay RM...

Страница 18: ...Control Unit Outputs Fire Supervisory Trouble DSC Subscribers Unit Fire Zone Inputs TIP TIP RING PGM1 DSC Keypad LCD4501 PK55XX 3G Wireless Transmitter 3G4010 T1 R1 TIP RING Zone Input PGM4 AUX Power...

Страница 19: ...TIP RING PGM1 DSC Keypad LCD4501 PK55XX 3G Wireless Transmitter 3G4010 T1 R1 PGM1 TIP RING Zone Input PGM4 AUX Power 12V 700mA RM1C ULC Relay PC5003C PC4050CR cabinet 3G HSPA 2G GPRS PSTN AC Input AC...

Страница 20: ...eless Network Supervision Relay Redundant Fire Alarm Transmission NOTE Use EOL resistor in series with N O contacts of the relay connected to PGM4 3 2 DC IN AUX 2 3 1 COM 4 1 COM T1 R1 TIP RING 4 PGM...

Страница 21: ...ork Supervision Relay Phone Line Supervision Relay and Redundant Fire Alarm Transmission NOTE Use EOL resistor in series with N O contacts of the relay connected to PGM4 5 6 KOhm 5 6 KOhm Wireless Net...

Страница 22: ...ees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights DSC ma...

Страница 23: ...AAAEQ TXXXX The digits represented by are the REN without a decimal point e g 03 is a REN of 0 3 For earlier products the REN is separately shown on the label Incidence of Harm If this equipment 3G401...

Страница 24: ...d damage from improper maintenance damage arising out of any other abuse mishandling or improper application of the products Items Not Covered by Warranty In addition to the items which void the Warra...

Отзывы: