English
IN ST AL LA TI ON M AN U AL
8. Maintenance
The appliance must be inspected once per year by a skilled installer in the field of gas-fired heating, and repaired if
necessary.
Check at least whether the appliance is working properly and safely.
!Caution
•
Always close the gas tap during maintenance work;
•
Check the gastightness after repair;
•
After replacing thermocouple 1 you should first tighten the gland nut by hand and then give it another
quarter turn with a suitable spanner;
•
You are not allowed to turn the pilot flame lower by using the settings on the gas control.
•
SS-absolutely do not clean the concentric system (internally) with a steel brush or metal sponge, for example.
This will damage the oxide skin and could lead to leaks in the system as a result of pitting corrosion.
Ø
If required, clean the following components:
•
the pilot burner (malfunction search diagram, Appendix 1);
•
the space surrounding the pilot burner;
•
the glass pane(s).
!Caution
Only clean a glass pane once it has reached room temperature.
!Caution
•
Avoid damage to the glass pane(s).
•
Avoid/remove fingerprints on the glass pane(s), as they will burn into the glass.
•
Clean the glass pane(s) as described in the user manual.
•
Regularly remove accumulated dirt, as it can burn into the glass.
•
Do not use the appliance when a glass pane is broken and/or cracked, until it has been replaced as
described from section 5.9.
!Caution
If necessary, replace the wood or pebble set correctly; as described from section 5.9.
Ø
Inspect the flue gas discharge system.
!Caution
You must always perform a final inspection.
Ø
Perform the inspection as described in chapter 7.
8.1 Parts
Parts requiring replacement can be obtained from your supplier.
18
Содержание Global Fires Global 55 CF RCE
Страница 30: ...E n g l i s h INSTALLATION MANUAL 30 38C 2108 0 A X 6 m B X 6 m X R 38C 2106 0 38C 2107 0 16 14 15...
Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 38P 0490 0 A B C 38P 0488 0 38P 0489 0 38p 0023 38P 0028 1 21 17 18 19 20...
Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 38P 0491 0 A 38P 0492 0 B 38P 0493 0 C 22 23 24...
Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38C 1940 300 150 450 150 150 A B 38c 2111 0 45 44...
Страница 35: ...E n g l i s h INSTALLATION MANUAL 35...
Страница 36: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven EN...