Installation

instruction

Surround C 11 

 Surround C 21

www.contura.eu

Summary of Contents for Surround C 11

Page 1: ...Installation instruction Surround C 11 Surround C 21 www contura eu ...

Page 2: ...PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material No minimum distance to rear 400 mm to side Other safety distances according to the installation instructions Risk of falling embers Approved Emissions from combustion CO 0 09 NOx 109 mg m3 OGC 50 mg m3 PM 29 mg m3 Surface temperatures Approved Cleanin...

Page 3: ...PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material No minimum distance to rear 400 mm to side Other safety distances according to the installation instructions Risk of falling embers Approved Emissions from combustion CO 0 07 NOx 99 mg m3 OGC 42 mg m3 PM 29 mg m3 Surface temperatures Approved Cleaning...

Page 4: ...be informed about the installation as this will affect the routines for regular chimney sweeping services WARNING The stove becomes very hot During operation certain surfaces of the stove become very hot and can cause burn injury if touched Be aware of the strong heat radiated through the hatch glass Placing flammable material closer than the safe distance indicated may cause a fire Pyre lighting ...

Page 5: ...ur Contura 11 21 is to be installed against a flammable wall the wall must be protected by a firewall or by the integrated protective screen that is sold an as accessory for these models A firewall must be at least the same width and height as the surround More information about the requirements made of the fire wall material is available in the separate instructions for the insert Remember that n...

Page 6: ...ed for combustion is approximately 30 m h applies with closed hatch Some installation alternatives are shown to the right The air duct connection on the stove has an external diameter of Ø100 mm In hot areas the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor aluminium tape It is important that the lead in between the pipe and the wall or floor is sealed using jo...

Page 7: ...ed C11 The dimension diagrams only show the minimum permitted installation distances for the insert When connecting to a steel flue also note the safety distance requirements of the flue The safety distance between an uninsulated flue and a combustible part of the building should be at least 300 mm The minimum distance to combustible parts of the building or interior decoration in front of the ins...

Page 8: ...65 875 The dimension diagrams only show the minimum permitted installation distances for the insert When connecting to a steel flue also note the safety distance requirements of the flue The safety distance between an uninsulated flue and a combustible part of the building should be at least 300 mm The minimum distance to combustible parts of the building or interior decoration in front of the ins...

Page 9: ...rround sides can be filled if so desired Top and rear connection can be made without any extra insulation or screening of connection pipes Protective screen When the surround is installed together with the integrated protective screen it is important that the airflow is not blocked For top connection the gap between the top of the surround and the chimney insulation must be covered by a cuff to sh...

Page 10: ...possible to connect the chimney with a backward angle through the height extension section that requires a seal above the angle Protective screen When the height extension section is installed the protective screen must be extended with a heat deflector through the height extension section Ensure that the heat deflector is also ventilated The top of the surround is also insulated using the insulat...

Page 11: ...he thickest sections of the base plate if possible If the accompanying protective screen is to be installed install it now See the separate instructions Installation of the surround is the same for Contura 11 respectively 21 Contura 11 is illustrated The type plate must be positioned under the bottom insulation of the ash pan ASSEMBLY ...

Page 12: ... to the base plate and adjust the feet so that the distance from the floor to the underside of the shelf is 469 mm Check that it is straight and stable 430 mm 40 mm If the insert is to be rear connected connect it now ASSEMBLY ...

Page 13: ...n the screws holding the side panels and remove them Use the same screws and screw holes to instead screw the hatch frame into place Check that the bottom corners line up with the shelf Hatch frame Shelf ASSEMBLY ...

Page 14: ...he sides of the insert Use the six installation screws supplied in the screw bag and the screws that are already in the upper corner of the insert Apply a bead of silicone on the base plate and then lift in the lower section sides ASSEMBLY ...

Page 15: ...ween the sides is the same at the front edge as at the rear edge and check that the sides are straight Draw a horizontal check line on the wall to simplify further installation Also check that the front edge of the hatch surround aligns with the inner edge of the concrete edges Applies to C 11C and C 21C Concrete Applies to C 11A C 11S C 21A C21S Sheet metal ca 33 mm 80 mm 80 mm ASSEMBLY ...

Page 16: ...GB 52 The panel variants front are adjusted for height using two adjustment screws In the event of removal and height adjustment use the following hook and pull out the lower door ASSEMBLY ...

Page 17: ...ides and bond them with silicone 3 mm 3 mm 3 mm Check that the second section is straight and that there is an even gap of approximately 3 mm between the frame and the concrete If necessary remove the lower front and adjust the insert ASSEMBLY ...

Page 18: ...upport the first side using a piece of tape so that it does not fall while the other side is installed Control measurements Control measurements Hang the safety rail between the third section sides and ensure that they are straight Check that the width is the same as section 1 at the front and rear edges ASSEMBLY ...

Page 19: ...heet of concrete the knock out in the top disc must be knocked out with a hammer Secure the top with a few blobs of silicone and press it forward so that it is tight to the front panel Bond the lower front with silicone Use the supplied installation angle to keep the front panel in position while the silicone cures ASSEMBLY ...

Page 20: ...o page 58 in combination with a non flammable wall and chimney connection straight backwards go to page 62 in combination with a non flammable wall and chimney connection angled backwards through the height extension section go to page 65 For installations without height extensions top connection to stainless steel flues is now possible follow the chimney manufacturer s instructions Then continue ...

Page 21: ...installed The top grilles are placed in position on the upper side and the lower grille pins are installed using the springs and lugs supplied not used when installing the height extension section Even off the edges between the concrete blocks by applying a little grout in the joints and then using the corner of a filling knife to scrape out the excess and retain the marked edges Fill and sand sma...

Page 22: ... it does not fall while the other side is installed Hang the safety rail between the sides and ensure that they are straight Check that the width is the same as section 1 at the front and rear edges Note the different installation methods of the height extension section When using a protective screen the airflow must not be restricted at any point Installation height extension sections C11 C21 In ...

Page 23: ...deways and hooking the tabs around the concrete Note that the heat deflector at the bottom edge must be positioned in front of the protective screen s heat deflector Install the left half of the heat deflector in the same way and screw the two halves together ASSEMBLY ...

Page 24: ...must be cut out to fit 25 mm The joint between the top and the chimney mantel must be tight to prevent convection air from the surround leaking out at the change height The weight of the chimney must be on the insert not the surrounding If the chimney is designed in another way the seal must be adapted to it Cut the large sheet of insulation so that it fits around the chimney mantle and position i...

Page 25: ... use shims where necessary Apply silicone along the front edge of the sides and bond the front in position If necessary use the adjustment screws to adjust the height of the panel variants The surround can now be joined and painted according to page 57 after which the grilles can be put in place ASSEMBLY Final inspection of the installation Before the stove is used it must be inspected by an autho...

Page 26: ...ide so that it does not fall while the other side is installed Note the different installation methods of the height extension section When the protective screen provided is not used the air outlet at the rear edge of the top panel must be plugged Installation height extension sections C11 C21 In combination with non flammable wall and chimney connection straight back or straight up Hang the safet...

Page 27: ...all insulation plate over the chimney hole in the top and connect the chimney The chimney must press the insulation together approx 5 mm so that it is tight but the weight must be on the insert and not the top panel If the start pipe has a diameter greater than 150 mm the hole in the insulation must be cut out to fit 25 mm The joint between the top and the chimney mantel must be tight to prevent c...

Page 28: ...ts between them look good use shims where necessary The sweeping hole in the concrete front is plugged using the concrete plug Bond it into place using silicone and fill it before painting The surround can now be joined and painted according to page 57 after which the grilles can be put in place Final inspection of the installation Before the stove is used it must be inspected by an authorised chi...

Page 29: ... at ordinary height according to page 47 56 Block the air outlet at the rear edge of the top panel using the seal plate that is bonded into position using silicone Apply silicone to the top of the surround and lift up the concrete sides of the height extension section Support the first side so that it does not fall while the other side is installed Hang the safety rail between the sides and ensure...

Page 30: ...ts around the chimney flue and position it so that it covers the whole of the top surface Place the left sealing plate so that it rests on the washer at the rear edge and the lock rail at the front Lift in the right sealing plates and screw them into place in each other Which holes are used depends on whether it is a Contura 11 or 21 ASSEMBLY ...

Page 31: ...To avoid gaps in the panel lines of the front area the height extension panel must be hung first without silicone Adjust the components so that the joints between them look good use shims where necessary Concrete variant Apply silicone along the front edge of the sides and bond the front in position Position the soot hatch loosely without silicone to make it possible to sweep through the front ASS...

Page 32: ...e inner front panel and can be removed when sweeping The surround can now be joined and painted according to page 57 after which the grilles can be put in place Final inspection of the installation Before the stove is used it must be inspected by an authorised chimney sweep Read the Instructions for Lighting the CI 10 CI 20 series before lighting the fire for the first time ASSEMBLY ...

Page 33: ...silicone First bond the base plate and then the back sides and upper section The woodbox can be turned both ways for positioning on either the left or right side If the surround has been raised using shims the log box must also be raised to align with the surround Installing the woodbox ASSEMBLY ...

Page 34: ......

Page 35: ......

Page 36: ...mensions and procedures described in these instructions at any time without special notice The current edition can be downloaded from www contura eu NIBE AB Box 134 285 23 Markaryd Sweden www contura eu 811041 IAV SE EX C11 C21 8 2014 11 04 ...