When using the wall terminal, place the terminal with a downward slope of 1 cm / metre towards the outside, in
order to prevent rain water from raining in.
5.8.4 Connection to an existing chimney
It is possible to connect the appliance to an existing chimney.
A flexible SS pipe is placed in the chimney with a fitting diameter at the flue gas discharge pipe, for the discharge
of flue gas. The surrounding space is used to supply combustion air.
The following requirements apply when connecting to an existing chimney:
•
only allowed when used in combination with the special DRU chimney kit. The installation regulation is also
supplied;
•
the internal dimensions should be at least 150 x 150 mm;
•
the vertical length has a maximum of 12 metres;
•
the total horizontal pipe length may have a maximum length that you can find in Appendix 2, Table 4;
•
the existing chimney has to be clean;
•
the existing chimney has to be tight.
For adjusting the appliance, the same conditions/instructions apply as for the concentric system described above.
11
Содержание Global Fires Global 55 CF RCE
Страница 30: ...E n g l i s h INSTALLATION MANUAL 30 38C 2108 0 A X 6 m B X 6 m X R 38C 2106 0 38C 2107 0 16 14 15...
Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 38P 0490 0 A B C 38P 0488 0 38P 0489 0 38p 0023 38P 0028 1 21 17 18 19 20...
Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 38P 0491 0 A 38P 0492 0 B 38P 0493 0 C 22 23 24...
Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38C 1940 300 150 450 150 150 A B 38c 2111 0 45 44...
Страница 35: ...E n g l i s h INSTALLATION MANUAL 35...
Страница 36: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven EN...