5
16012 rev 2012-02-29
hose from the sink into this drum (item 4 illustration 2). Make
sure that the hoses are properly led well down into the drum,
and that the opening is well sealed by the tapered plug.
Take the second drum, the one full of solvent, and pour half of
its contents directly into the gun cleaner’s sink (item 2 illustra-
tion 1). The solvent that is poured in will drain into the drum
underneath the gun cleaner. Make sure to have the ventilation
running during this procedure.
Place the second drum, now half full, on the fl oor on the right-
hand side of the fi rst drum (item 3 illustration 2). Insert the
second group of hoses containing a white hose into this drum
(item 5 illustration 2). Make sure that the hoses are properly
led into the drum all the way down to the bottom, and that the
opening is well sealed by the tapered plug.
The solvent system is now fi lled-up. Both drums should be half
full. The left-hand drum, contains the solvent that will be recir-
culating for the automatic wash cycle, and the right-hand drum
contains clean solvent for rinsing. The contents of the right
drum will gradually be used up and transferred to the left drum.
Operating instructions
Operating instructions should be formulated on the basis of
this manual and translated into the language spoken by the
employees. It should always be available close to the machine.
To avoid confusion, the employees must be informed about the
solvent currently being used in the machine.
OPERATING INSTRUCTIONS
Empty the spray-gun of any residual paint into a separate spills-
dish.
Open the main valve for compressed air (item 7 illustration 1).
Open the lid for the automatic washer (make sure it `clicks` into
the full open position).
Place the spray-gun inside (see illustration 5).
Be sure to fi t the trigger clip following illustration 6, and to
push the spray-gun up against the nozzle for the paint-channel
(item 1 illustration 5) before you lock it into position with aid of
the magnets of the trigger clip.
If you prior to cleaning prefer to remove the Air-cap and the
needle of the spray-gun, then place those items as shown by
arrow 5 in illustration 5.
Close the lid, and start the automatic pre-wash cycle by press-
ing the foot pedal No.8 in illustration 1. The spray-gun will now
be automatically cleaned for approx. 1.5 minutes with circulat-
ing solvent.
When the automatic pre-wash cycle is completed, the spray-
gun can be rinsed with clean solvent. The rinsing pump is
activated by pressing the foot pedal No. 9 in illustration 1, and
continues to work for as long as the pedal is depressed. The
pump will feed approx. 75 cc of solvent per pump stroke.
2-3 pump strokes
are generally suffi cient for one rinse. Less if
the solvent has recently been changed.
When the cleaning procedure is completed, the lid can be
opened and the spray-gun taken out. It can now be manually
further washed or rinsed if required.
By pressing foot pedal No.10 in illustration 1 (NOTE: press it all
the way down !), recirculating solvent will be fed through the
brush placed in the sink (item 1 illustration 7).
By pressing foot pedal No.11 in illustration 1, clean solvent
will be fed through the spray-nozzle placed in the sink (item 2
illustration 7).
The brush and spray-nozzle in the sink can be used indepen-
dently of the automatic washer at any time, provided that the
lid for the automatic washer is closed. The intensity of the spray
can be adjusted with the air-fl ow restrictor (item 1 illustration
14).
Connect the spray-gun to the air-line on the left side of the
machine (item 4 illustration 1), and blow out the spray-gun
through the funnel in the sink (item 3 illustration 7). By using
this funnel, you prevent the fumes from spreading within the
premises.
Finally, the spray-gun can be blown dry by using the air-gun on
the right side of the unit (item 12 illustration 1).
Close the lid after cleaning.
SERVICE
Weekly:
– Remove the strainer at the bottom of the automatic washer
(item 2 illustration 5) and clean it,
do not forget to re-fi t it!
Monthly:
– Remove the fi ve nozzles automatic washer and clean them
with clean solvent. (see illustration 8).
When changing drums:
– Check and if necessary clean the strainer on the suction
hose for circulating solvent.
Содержание Boxer Double S DB22S