8-11
CH 8/ Reports
Compliance History
QOS Status
Summary
EN50160 provides a historical summary of the QOS compliance evaluations made. The
standard monitoring period is one week, usually beginning Sunday at 00:00 (midnight).
Any compliance evaluation performed in less than one week will receive an Evaluation
Status marked as Incomplete, and Compliance marked as Undetermined. For
completed monitoring periods, Compliance status may either be PASS or FAIL if all of
the specified parameters is within limits for 95% or more of the monitoring time period.
A PASS or FAIL status is hyperlinked to the Compliance Statistical Bar Chart.
Compliance
History table
Compliance History displays a table that summarizes the QOS evaluation status. From
the EN50160 screen on page 8-3, press History. The Compliance History table will
appear as shown below.
Evaluation Status: The EN50160-specified compliance evaluation period is a 7-day
(one week) period. The evaluation status is Complete if monitoring is done within one
full week, or Incomplete if monitoring is done in less than one week. An evaluation
status is Incomplete under the following scenarios:
• It is the current evaluation period and it has simply not completed.
• It is a previous evaluation period but not enough data samples were included in the
statistical analysis. This may be due to the following reasons: data was not collected
or too many samples were tagged as unusable due to rms variations.
Continued on next page
MARK472
scroll through previous/
next items in the list
PASS (green) or FAIL (red) status is linked to
the Compliance Statistical Bar Chart (p. 8-8)
Содержание PowerVisa
Страница 1: ...PowerVisaTM USER S GUIDE DRANETZ BMI 1000 New Durham Road Edison New Jersey 08818 4019...
Страница 13: ...xiii Dranetz BMI PowerVisaTM...
Страница 14: ......
Страница 78: ...4 16...
Страница 136: ...6 22...
Страница 158: ...7 22...
Страница 204: ...A 10...
Страница 221: ...C 5 APPENDIX C Battery Specifications and Replacement Procedure Battery removal diagram...
Страница 222: ...C 6...
Страница 224: ...D 2...
Страница 248: ...F 4...
Страница 251: ...LEVEL 100 1 Start Menu Automatic Setup MARK101a MARK104 MARK103a G 3 MARK100 To Level 001 VISA123 MARK104a...
Страница 257: ...LEVEL 150 Instrument Settings MARK151 VISA152 PVISA155 MARK156 MARK157 MARK158 MARK160 MARK159 G 7...
Страница 259: ...MARK201 LEVEL 200 Scope Mode MARK202 MARK205 G 9...
Страница 260: ...MARK301PG LEVEL 300 1 Meter Mode Standard MARK302PG MARK303PG MARK305PG MARK307PG MARK306PG MARK304PG G 10...
Страница 261: ...LEVEL 300 2 Meter Mode Distortion MARK315PG MARK313PG MARK314PG MARK312PG MARK316PG MARK311PG G 11...
Страница 268: ...Level 112_601 Advanced Options Journal Interval MARK112_401 MARK112_402 MARK112_403 MARK112_404 MARK112_405 MARK112 G 18...
Страница 269: ...MARK112b LEVEL 112_701 Advanced Options EN50160 Options MARK112c G 19...
Страница 272: ...MARK431 LEVEL 430 Trend MARK432 MARK437b MARK433PG MARK436 MARK434 MARK435 MARK438 MARK440 MARK441 MARK439 MARK437 G 22...