Installation
(for qualified installers only)
29
© Travis Industries
4140514
100-01374
Vent Configuration: 5x8” Diameter Vent (Hor. Or Vert. Termination)
Use 5x8” diameter vent.
NOTE
: The included pipe shield is not required and may be discarded. The included
firestops may be discarded.
The termination must fall within the shaded area shown in the chart. Use the indicated
restrictor positions.
NOTE: Vertical Terminations Require a minimum 10’ rise.
Up to 3 elbows (45° or 90°) may be used. Only one horizontal elbow may be used.
5 feet (1.5m)
0 feet
0 feet
5 feet (1.5m)
0 feet
20 feet (6m)
20 feet (6m)
5 feet (1.5m)
10 feet (3m)
5 feet (1.5m)
10 feet (3m)
0 feet
15 feet (4.5m)
20 feet (6m)
10 feet (3m)
15 feet (4.5m)
15 feet (4.5m)
20' (6m) max
10 feet (3m)
15 feet (4.5m)
40' (12m) max
25 feet (7.5m)
30 feet (9m)
35 feet (10.5m)
40' (12m) max
25 feet (7.5m)
30 feet (9m)
35 feet (10.5m)
25 feet (7.5m)
30 feet (9m)
35 feet (10.5m)
40 feet (12m)
45 feet (13.5m)
50 feet (15m)
55 feet (16.5m)
60 feet (18m) max
25 feet (7.5m)
30 feet (9m)
35 feet (10.5m)
40 feet (12m)
45 feet (13.5m)
50 feet (15m)
55 feet (16.5m)
60 feet (18m) max
Minimum 2' rise (Hor. Term.)
Intake Restrictor # 1
Exhaust Restrictor # 1
Diffuser Closed
Intake Restrictor # 2
Exhaust Restrictor # 3
Diffuser Open
Intake Restrictor # 3
Exhaust Restrictor # 6
Diffuser Open
Minimum 10' rise (Vert. Term.)
This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.
This is considered a
vertical elbow
Horizontal length is calculated by adding
both lengths of horizontal run
(Horizontal Length = H1 + H2).
H1
H2