18 Installation
(for qualified installers only)
© Travis Industries
4140514
100-01374
Gas Line Location
NOTE FOR RIGID PIPE:
When using rigid pipe, you may wish to disconnect the shutoff valve from the fireplace
and route the pipe through the fireplace wall. First, disconnect the gas line from the shutoff valve (see step 1
below). Then remove the shutoff valve from the cover plate (4 screws outside fireplace). The pipe may be routed
through the cover plate and the shutoff valve and gas line may be re-attached inside the fireplace.
Gas line may be plumbed from the left side (stock) or below. See illustration and table below to determine gas line location.
a
b
Left Side Gas Line Location (Stock)
4” (102mm)
3.25” (83mm)
Baseplate Gas Line Location
7.75” (197mm)
16” (407mm)
Relocating the Gas Line to the Baseplate
1. Disconnect the gas line from the shutoff valve (3/4” wrench). Gas line is located inside the fireplace on the left side.
2. Remove the screw that holds the shutoff valve plate in place (1/4” nutdriver). Remove the shutoff valve plate.
3. Remove the cover plate from the bottom of the fireplace (it is held in place in the same fashion as the shutoff valve plate).
Attach it to the left side of the fireplace.
4. Attach the shutoff valve plate to the bottom of the fireplace. Route the gas line to the bottom and re-attach the gas line to
the shutoff valve. Make sure to leak test the entire gas line.
Framing Opening
a
b
a
b