53
Technical Data
Environmental conditions (Sensing Head Polytron SE Ex PR M and SE Ex LC M):
Operation:
Temperatures see above
700 to 1300 hPa
in hazardous areas: 800 to 1100 hPa
5 to 95% rel. humidity, non-condensing
Storage (also for replacement sensors):
–40 to + 65
o
C
700 to 1300 hPa
10 to 90 % rel. humidity, non-condensing
Sensing Head Polytron SE Ex HT M
Operating parameters
— constant sensor current
240 / 270 mA
— voltage at test points
528 / 594 mV (Central Controller Polytron SE Ex)
Electrical and thermal parameters:
— maximum power consumption at 270 mA
1.0 W
maximum voltage
60 V
— minimum ambient temperature:
–50
o
C
— maximum ambient temperature:
temperature class assignment:
II 2G: T3:
150
o
C
II 2D: T200:
150
o
C
Enclosure protection acc. to EN 60 529:
IP 65
Device description acc. to 94/9/EG:
Sensing Head Polytron SE Ex HT M:
see Dräger Safety type plate on the enclosure:
Dräger Safety, D-23560 Lübeck, Germany
Sensing Head SE Ex HT M
year of construction by serial number
1)
1. Ex sensor HT M:
Dräger Safety, D-23560 Lübeck, Germany
Ex sensor HT M
II 2G EEx d IIC T3
II 2D IP 6X T200
o
C
DMT 97 ATEX E001 X
CE 0158, year of construction by serial number
1)
2. Enclosure (junction box):
see Dräger Safety type plate on the enclosure:
Flameproof Electrical Enclosures Ltd., Oldbury, England
Typ Range 2000
II 2G EEx e II T3
II 2D IP 66 T 200
o
C
SIRA 99 ATEX 3179
CE 0518, year of construction
__________________________
1) Year of construction is coded by the third capital letter of the serial number on the type plate:
S = 2002, T = 2003, U = 2004, W = 2005, X = 2006, Y = 2007, Z = 2008, A = 2009, B = 2010, C = 2011, D = 2012, etc.
Example: Serial number ARSH-0054, the 3rd capital letter is S, so the year of construction is 2002.