Technical Data
52
Technical Data
Sensing Head Polytron SE Ex PR M
Operating parameters
— constant sensor current
240 / 270 mA
— voltage at test points
528 / 594 mV (Central Controller Polytron SE Ex)
Electrical and thermal parameters:
— maximum power consumption at 270 mA
1.0 W
— maximum voltage
60 V
— minimum ambient temperature:
–50
o
C
— maximum ambient temperature:
temperature class assignment:
II 2G: T4:
85
o
C, T5:
55
o
C, T6:
40
o
C
II 2D: T135:
85
o
C, T100:
55
o
C, T85:
40
o
C
Enclosure protection acc. to EN 60 529:
IP 65
Device description acc. to 94/9/EC:
Dräger Safety, D-23560 Lübeck, Germany
Sensing Head SE Ex PR M
II 2G EEx de IIC T4/T5/T6
II 2D IP 6x T85/100/135
o
C
DMT 97 ATEX E006 X
CE 0158, year of construction by serial number
1)
Sensing head Polytron SE Ex LC M
Operating parameters
— constant sensor current
276 mA
— voltage at test points
607 mV (Central Controller Polytron SE Ex)
Electrical and thermal parameters:
— maximum power consumption at 276 mA
1.0 W
— maximum voltage
60 V
— minimum ambient temperature:
–40
o
C
— maximum ambient temperature:
temperature class assignment:
II 2G: T4:
85
o
C, T5:
50
o
C, T6:
40
o
C
II 2D: T135:
85
o
C, T100:
50
o
C, T85:
40
o
C
Enclosure protection acc. to EN 60 529:
IP 65
Device description acc. to 94/9/EC:
Dräger Safety, D-23560 Lübeck, Germany
Sensing Head SE Ex LC M
II 2G EEx de IIC T4/T5/T6
II 2D IP 6x T85/100/135
o
C
DMT 97 ATEX E006 X
CE 0158, year of construction by serial number
1)
__________________________
1) Year of construction is coded by the third capital letter of the serial number on the type plate:
S = 2002, T = 2003, U = 2004, W = 2005, X = 2006, Y = 2007, Z = 2008, A = 2009, B = 2010, C = 2011, D = 2012, etc.
Example: Serial number ARSH-0054, the 3rd capital letter is S, so the year of construction is 2002.