![Dräger Polytron 8000 Series Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/drager/polytron-8000-series/polytron-8000-series_technical-manual_2526576083.webp)
Technical Manual
|
Dräger Polytron
®
8000 Series
83
Factory default settings
15.3.2 Polytron
®
8100 EC
Hydride SC 6809980
0.3
1
1
0.1
0.2
HCN
6809650
10
50
50
10
20
HCN LC
6813200
5
50
50
4
8
NO
2
6809655
5
10
100
2
4
NO
2
LC
6813205
1
5
20
0.5
1
SO
2
6809660
5
10
100
2
4
CI2
6809665
1
10
50
0.5
1
H
2
O
2
LC
6809705
1
5
300
1
2
H
2
O
2
HC
6809675
1000
4000
7000
200
2800
H
2
6809685
500
1000
3000
200
400
COCI2
6809930
0.1
1
20
0.1
0.2
Hydrazin
6810180
0.3
1
5
0.1
0.2
HCI SC
6809640
20
30
100
5
10
AC
6810595
3
10
30
2.5
5
PH3/AsH3
6809695
0.3
1
20
0.1
0.2
NH3 HC
6809645
300
1000
1000
50
100
NH3 LC
6809680
50
100
300
12.5
25
NH3 FL
6813260
50
100
300
12.5
25
NH3 TL
6813095
50
100
300
12.5
25
NH3 TH
6800055
300
1000
10000
50
100
Ozon
6814005
0.5
1
5
0.1
0.2
Sensor
Part number
Range
Default value
Min.
Default
Max.
A1
A2
Menu
Default setting
Range
A1 Alarm
Depending on
the sensor
A2 Alarm
Depending on
the sensor
Hysteresis for A1
alarm at direc-
tion rising
0
0 to A1
Hysteresis for A2
alarm at direc-
tion rising
0
0 to A2
Calibration inter-
val [days]
Depending on
the sensor
0 to 720
Display capture
offset
20.9 Vol% (O
2
)
0 to 25 Vol% (O
2
LS)
0 to 100 Vol% O
2
)
Display capture
low
-0.25 Vol% (O
2
) 0 to -0.75 Vol%
Display capture
high
0.25 Vol% (O
2
)
0 to 0.75 Vol%
Full scale deflec-
tion
25 Vol% (O
2
,
O
2
LS)
5 to 25 Vol% (O
2
LS)
5 to 100 Vol% O
2
)
Содержание Polytron 8000 Series
Страница 2: ...2 Technical Manual Dräger Polytron 8000 Series This page has been left blank intentionally ...
Страница 109: ......