NetGuardian 832A/864A G5 Web Browser 

March 6, 2020

D-UM-NETG5.12101

Firmware Version v.5.6D

Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs.

Содержание NetGuardian 832A G5

Страница 1: ...USER MANUAL NetGuardian 832A 864A G5 Web Browser March 6 2020 D UM NETG5 12101 Firmware Version v 5 6D Visit our website at www dpstelecom com for the latest PDFmanual and FAQs...

Страница 2: ...f this manual Notice Revision History March 6 2020 December 11 2019 November 15 2019 October 21 2019 March 5 2019 August 2 2018 May 18 2018 September 6 2017 December 7 2016 May 20 2016 April 30 2015 J...

Страница 3: ...eld 2 5 1 1 12 T1 E1 WAN Configuration 2 5 1 2 13 Setting Up SNMPv1 v2c or v3 2 5 2 14 Filter IPA Config and Operation 2 5 3 17 Changing Craft Port Communication Settings 2 5 4 20 Configuring Modem Po...

Страница 4: ...from an Alarm Point s Change of Status 2 16 2 53 Echoing alarm points to relays 2 16 2 1 53 Oring echoed alarm points 2 16 2 2 53 Making Control Relays exclusive from each other 2 16 2 3 54 Derived C...

Страница 5: ...ch Status 3 11 78 Monitoring Camera Activity 3 12 78 Pan and tilt Camera Controls 3 12 1 79 Monitoring Multiple Cameras 3 12 2 79 Appendixes 4 80 Appendix A Display Mapping 4 1 80 System Alarms Displa...

Страница 6: ...bove Fig 1 2 NetGuardian 832A G5 has the capacity to monitor IP aware devices network presence and also interfaces discrete alarm points and controls at your network sites Potential Problems using Web...

Страница 7: ...r Pager and Email Notification Selectively assign alarm points to specific pager and email notification recipients The NetGuardian can be configured to send pager notifications only for Critical or Ma...

Страница 8: ...s 2 After connecting to the NetGuardian s IP address enter your password and click Submit see Figure 2 1 Note The factory default password is dpstelecom 3 In the left frame there is Monitor menu butto...

Страница 9: ...nter the number of times the RADIUS server should retry a logon attempt Time out Enter in the number of seconds before a logon request is timed out Servers 1 2 IPA Enter the IP address of the RADIUS s...

Страница 10: ...Click Submit to save your system information settings If using email pager type refer to Section 2 5 for correct name and location field formatting Fig 3 2 Configure the system information by selectin...

Страница 11: ...ails DNP Address This is the DNP3 polling address of the NetGuardian This value can range from 0 65519 DNP TCP Port This option allows you to select the port for DNP3 polling over LAN Set to 0 to disa...

Страница 12: ...rity dial back functions in the Logon Profile screen See section for dial back and logon profile configuration information The factory default password is dpstelecom DPS Telecom strongly recommends th...

Страница 13: ...g steps to create logon profiles 1 From the Edit menu select Logon then click on the Available link See Figure 2 3 2 Enter the user information in the appropriate fields See Table 2 B for field and ac...

Страница 14: ...em Enables the user to call into the unit Telnet Enables the user to have Telnet access to the unit PPP Enables the user to access the PPP server with the user defined password Table 2 B Logon profile...

Страница 15: ...the Edit menu 2 Enter the appropriate information for your ethernet port in the corresponding fields 3 Click Submit Data to save your configuration settings Fig 2 5 Ethernet port configuration is acc...

Страница 16: ...nections attached but uses only the primary LAN Net1 When a LAN failure occurs the unit makes the switch to the secondary LAN connection Net 2 to maintain visibility Autoswitch Used with Backup Mode U...

Страница 17: ...NetGuardian automatically attaches a unique suffix to each alarm point For example if the base URL is http www dpstelecom com the link for the base alarm at point 1 would be http www dpstele com base...

Страница 18: ...WAN MUX enter the ID number of the port on the WAN MUX to which you ve connected the NetGuardian This number must be unique from other NetGuardians connected to the same WAN MUX If using the NetGuardi...

Страница 19: ...to your managers 11 Click Submit to save your system information settings Fig 2 6 SNMP Menu Globals Source Address Allows the user to configure the origination IP address of an SNMP trap Follow SNMP t...

Страница 20: ...entifies the security modes available when SNMPv3 is utilitized The modes are as follows No Auth No Priv This access mode does not require authentication and does not require encryption This mode is t...

Страница 21: ...and passwords that should be used for sending a v3 Trap Table 2 E Fields in the Edit SNMP settings Note If you are using SNMPv3 any changes to the Engine ID or passwords will require a reboot At boot...

Страница 22: ...Once enabled only the IP addresses in the table will be allowed access to the NetGuardian 4 Select to Enable IPATable 5 Choose an IPAFilter Mode Standard or Enhanced If you change the IPA Filter Mode...

Страница 23: ...ng your IP filtering rules in Enhanced IPAFilter Mode 1 IPA Filter Test The Configure Simulated Packet tool may be used to test your chosen firewall rules You can choose an Interface NIC IP Address TC...

Страница 24: ...be skipped during evaluation Rule action Choose whether traffic matching this rule will be dropped or accepted Source address or network Choose which IP addresses all or subnet or single address will...

Страница 25: ...the craft port to 300 600 1200 2400 4800 9600 19200 38400 57600 115200 Default Baud is 9600 3 Under the Wfmt word format field select the appropriate data bits parity and stop bits setting to match yo...

Страница 26: ...ur modem port settings Fig 2 10 Change the modem settings from the Edit menu Ports screen Command Description A Answer command Bn Select communications standard D Dial P Pulse dial T Tone dial R Conne...

Страница 27: ...ion 2 4 7 1 to select the appropriate data port type setting for your application GLDs uses the expansion port and NetGuardian Expansions use port 7 See their respective user manuals for detailed conf...

Страница 28: ...n between the NetGuardian G5 and the 216 expansion By selecting the number of 216 expansion units from the NGDdx options dropdown menu the NetGuardian G5 will configure port 1 for polling this type of...

Страница 29: ...o single port UDP Makes reach through available at UDP ports up to 4 UDP ports available CHAN Creates logical bridge to odd even partner The odd even partners are pairs of 1 2 3 4 5 6 and 7 8 This all...

Страница 30: ...ink at user specified intervals MUXIN Multiplexer In For use in specifying the multiplexer in port All MUXOUT ports will go through this single MUXIN There can be only one MUXIN configured at any time...

Страница 31: ...is selected the NetGuardian will negotiate the connection for the user To break the SPS8 connection and return to the normal NetGuardian interface type and press Enter Hot Tip SPS8 ports do not suppor...

Страница 32: ...onnection Once you define a NetGuardian data port as NTCP you can configure its options in the Nailed TCP Connection Configuration table located just below Note Each of the Data Port IDs 1 8 correspon...

Страница 33: ...are preferred Some users prefer to disable direct proxy for all connections in order to enforce the password security provided by the TTY interface One way to disable proxy connections is to set the...

Страница 34: ...tion from the NetGuardian via dial up and display alarm information alarm description and threshold status Only activates if DCP Poller is inactive TCP ASCII Paging Alarm status notification via multi...

Страница 35: ...iption 9 Alarm status 01 Net Guardian 14 99 1 1 3 1 TOWER LIGHTS Alarm 7 36 8 25 2008 1 2 3 5 6 7 8 9 4 Fig 2 17 Alpha numeric pager description 2 6 2 SNPP Notification Setup The alpha numeric pager c...

Страница 36: ...16 Note Pager IDs are used in the alarm provisioning screen to designate the primary and secondary person device being paged when an alarm condition occurs or clears 2 Under the Type column select Tex...

Страница 37: ...purposes It is not necessarily a real email address that can be replied to unless one is entered 2 6 5 1 SMTP POP3 Authentication Support This section contains steps to configure your NetGuardian for...

Страница 38: ...status from multiple SNMP managers in addition to the global managers which are setup from the SNMP menu Use the following steps to configure the SNMP notification settings 1 From the Edit menu Notif...

Страница 39: ...higher level master This connection must be established by the master Any applicable alarm activity occurring prior to an established connection will be discarded Use the following steps to configure...

Страница 40: ...cing a comma after the phone number initiates a two second pause per comma This allows enough time for the pager to answer before the NetGuardian sends the alarm information The Baud Wfmt and IPAfield...

Страница 41: ...rms see section Configuring Base Discrete Alarms Use the following steps to define alarm messages for alarm point groups 1 To define the point groups select Point Group from the Edit menu 2 Then enter...

Страница 42: ...an SNMP trap for that alarm point in the event of an alarm condition Leave the box blank if you do not wish the NetGuardian to send an SNMP trap 5 Set the primary and secondary pagers with a pager ID...

Страница 43: ...lue field enter the appropriate amount of time 1 127 6 Under the Units column click on the drop down menu and select the appropriate unit min sec hour 7 Under the Type column click on the drop down me...

Страница 44: ...er the ID of the Event qual you would like to modify 3 Then input the Type Display Point Value and Timer units for each ID Where Display is 1 16 Point is the qualifying alarm point The Timer value can...

Страница 45: ...n SNMP trap for that alarm point Selecting the box will set that point to send a SNMP trap leaving the box blank will set that point to not send an SNMP trap 3 Set the primary and secondary pagers wit...

Страница 46: ...dings are used when setting up SNMP alarms The Edit Variable Bindings menu Variable Bindings Id Identification number for the variable binding OID OID of the variable binding Note Using a in this fiel...

Страница 47: ...ls Enterprise OID Enterprise OID for SNMPv1 or Trap OID for SNMPv2c Generic Generic Trap number for SNMP v1 only Specific Specific Trap number for SNMPv1 only Variable Binding OID If defined additiona...

Страница 48: ...l of the amount of time a point is in an alarm state to send an Accumulation Event system alarm once the total time exceeds a defined threshold Refer to Table 2 I for field descriptions Use the follow...

Страница 49: ...ry pagers with a pager ID from your defined pager list See Section Setting up Notification Methods for more information Note The NetGuardian G5 will notify both the primary and the secondary notificat...

Страница 50: ...ption field enter a description for each analog channel being utilized 3 Check the Trap box if you would like to receive an SNMP trapped when a threshold is crossed for this channel 4 Enter the ID of...

Страница 51: ...the temperature battery or air flow sensor you must dedicate an analog port to each one see user manual for connection information Note Ambient room temperature will be cooler than the NetGuardian in...

Страница 52: ...e 1 enter integrated percent in the box to the right of VDC Look for calibration check box only visible for air flow sensor this is a control not a configuration 2 Supply maximum possible air flow whi...

Страница 53: ...onfigured sensor will automatically fill out a ROMID cell The color of each cell will signify its configuration status If the ROMID cell is yellow the sensor is detected but is not yet configured If t...

Страница 54: ...Sometimes simply checking the alarm threshold values of your analog sensors is not enough The Analog Delta feature allows you to define a discrete alarm to be triggered when your analog value changes...

Страница 55: ...ge difference See Analog Sensors for more info on linear scaling using Reference 1 and Reference 2 Time Period How often the NetGuardian checks the analog value for a change Alarm Display Point Which...

Страница 56: ...us will appear underneath in blue Current Stats will show the most recent delta calculation and Previous Alarm will show the most recent delta that was large enough to trigger the alarm A delta is cal...

Страница 57: ...that point to not send an SNMP trap 5 Under the Group column enter the appropriate point group ID see section Defining Point Groups 6 Click Submit Data to save the configuration settings Hot Tip The...

Страница 58: ...allows the user to echo an alarm point state to activate a relay Any of the NetGuardian s discrete alarms system alarms ping alarms or analog alarms may be echoed to activate a relay in the event that...

Страница 59: ...Alarming Control relays and virtual alarms can be created from derived formulas using the following operations _OR Set the current operation to OR _AN Set the current operation to AND _NO Set the curr...

Страница 60: ...DD PP is used to specify the display and point number of the alarm to be mapped to the control 2 16 4 1 Echoed Mode An echoed control reflects the state of the alarm for which it is assigned The user...

Страница 61: ...lification feature 1 From the Edit menu click on the Event Qual drop down menu and select the appropriate group 2 In the Display text box type 11 3 In the Point text box type the number of the relay y...

Страница 62: ...ding inactivity time for data ports and discrete alarm detect time Ping timer settings allow you to balance network traffic against alarm response times Although you can change the values from their d...

Страница 63: ...in Display 11 Point 63 See Appendix A Display Mapping 8 DCP Poll Delay is the interval between polling of the expansion unit s by the NetGuardian G5 Calid time interval is between 1 second and 24 hou...

Страница 64: ...ime 2 18 Fig 2 34 The current date and time can be entered from the Date and Time screen or from an SNMP manager The date is entered in the mm dd yyyy format and the time is entered in the hh mm ss fo...

Страница 65: ...If you do not want your NetGuardian to sync with an NTP server simply set the Time Server IPA to 255 255 255 255 Note If Time Server IPA is set to 255 255 255 255 you will be able to manually adjust...

Страница 66: ...t 3 Select the type of DSCP device 4 Click Submit Data to save your settings 5 Reboot the NetGuardian 6 Once the NetGuardian comes back online give it a few moments to initialize the wireless radio Yo...

Страница 67: ...frequency and will remember the last read value Input 0 to disable this feature Level Threshold If the propane level reading differs by the Level Threshold value from the previous reading then the mos...

Страница 68: ...r CDMA or GPRS in the port menu and Submit Data The NetGuardian will then tell you what Phone value to enter via the Use text Username Enter the client s Username Password Enter the client s Password...

Страница 69: ...be sent to inform the user s of a network lost event After a user specified duration of time configured via PPP Connection in the Edit Timers menu the NetGuardian will disable Cellular PPP and switch...

Страница 70: ...is given to the guest dialing in This must be a valid and available IP address for the subnet on the LAN you will be connecting to the same one the NetGuardian is connected to 4 Click Submit Data to...

Страница 71: ...r the Access Privileges section check the PPP and Telnet boxes 12 Click Submit Data to save the configuration settings 13 Select Reboot in Edit menu to reboot the NetGuardian See section Rebooting the...

Страница 72: ...s 4541600 and direction is enabled users need to type in 45416001 to enter or 45416004 to exit ECU in Dual Proxy Mode Latch on exit Allows users to unlock doors from the inside proxy reader keypad whe...

Страница 73: ...for the first floor In Facility Broadcast Field descriptions for options available in the BAC 2 21 1 Entry Exit Logging You can enable entry and exit logging for your Building Access Controller by ch...

Страница 74: ...in keypad or proxy at a door ECU with Exit Mode enabled Make sure Direction Enabled is unchecked Note Doors with Exit Mode enabled cannot process entry requests For more information about In Facility...

Страница 75: ...ns below are relevant to Internet Explorer 5 5 and 6 0 only 1 With the Web browser open Internet Explorer version 5 5 or later click on Tools and select Internet Options from the drop down menu 2 Clic...

Страница 76: ...uire a reboot to take effect The window footer will display the text Reboot Needed if a reboot is necessary to initiate changes Monitoring Your NetGuardian 3 The Web browser allows you to do full syst...

Страница 77: ...ing targets analogs system alarms and any NetGuardian discrete expansions Monitoring Base Alarms 3 2 Fig 3 2 Viewthe status of the Base Alarms from the Monitor Base Alarms screen This selection provid...

Страница 78: ...has been triggered Under the State column the description defined in Edit menu Point Groups will appear in red if an alarm has been activated The description defined in Edit menu Point Groups will be...

Страница 79: ...uild option D Wire Sensors 1 8 and 9 16 links will appear under the Analogs link These pages add the ROMID columns to the original analog tables If a sensor is not detected its ROMID font will appear...

Страница 80: ...endix A for system alarm trap numbers Operating Controls 3 8 Fig 3 7 Issue controls from the Monitor Controls screen Use the following rules to operate controls 1 Select Controls from the Monitor menu...

Страница 81: ...alarms while retaining intruder alarms Note To manage Event Logs by group select Summary from the left menu then select the Group you wish to manage From here you can view events unique to each group...

Страница 82: ...r the eight data ports by displaying transmit or receive activity in ASCII for the selected port See Appendix C ASCII Conversion for specific ASCII symbol conversion Fig 3 9 1 To viewthe data being tr...

Страница 83: ...Status Speed and Packets from both the 10 100 1000 Base Switch and SFP Fiber ports Monitoring Camera Activity 3 12 Fig 3 10 Monitor live streaming video via the NetGuardian s Web browser Select the S...

Страница 84: ...click on the Program link To adjust the brightness click on the to darken the image screen or to brighten it Click on STD to return to the default settings Fig 3 11 Use the arrowbuttons to use the pan...

Страница 85: ...e button Appendixes 4 Appendix A Display Mapping 4 1 Port Address Display Points Description Set Clear 99 1 1 1 32 Discrete Alarms 1 32 8001 8032 9001 9032 99 1 1 33 64 Discrete Alarms 33 64 864A Unus...

Страница 86: ...8 99 1 13 33 48 NDGx 4 Alm 1 16 6065 6128 7065 7128 99 1 13 49 50 NDX 4 Ctl 1 2 6065 6128 7065 7128 99 1 14 1 16 NGDx 5 Alm 1 16 6129 6192 7129 7192 99 1 14 17 18 NDX 5 Ctl 1 2 6129 6192 7129 7192 99...

Страница 87: ...769 6832 7769 7832 99 1 25 1 32 NGDx 7 Alg 2 6833 6896 7833 7896 99 1 25 33 64 NGDx 8 Alg 2 6833 6896 7833 7896 99 1 26 1 32 NGDx 1 Alg 3 6897 6960 7897 7960 99 1 26 33 64 NGDx 2 Alg 3 6897 6960 7897...

Страница 88: ...064 7001 7064 99 1 13 NetGuardian Expansion 1 Relays 1 8 or NetGuardian 480 as DX Relays 1 4 6065 6072 7065 7072 99 1 13 NetGuardian 480 as DX Alarms 65 80 6081 6096 7081 7096 99 1 14 NetGuardian Expa...

Страница 89: ...us Poll Inactive 8672 9672 33 Unit Reset 8673 9673 34 PPP Backup Mode 8674 9674 35 Server Restore 8675 9675 36 Lost Provisioning 8676 9676 37 DCP Poller Inactive 8677 9677 38 NET1 not active 8678 9678...

Страница 90: ...vent may be associated with the alarm to force a call out or trap Disable Building Access Control BAC by setting the BAC Unit ID to 0 If Building Access is being used then investigate the ECU alarm so...

Страница 91: ...iod of time Check configuration of DSCP Poller Check battery power Make sure signal is not physically obstructed 28 Wireless Sensor Power Fault Power to DSCP unit is shorting or cannot provide enough...

Страница 92: ...TY interface or contact DPS for possible RMA 42 No Dial Tone During dial out attempt the unit did not detect a dial tone Check the integrity of the phone line and cable 43 SNMP Trap not Sent SNMP trap...

Страница 93: ...hardware is RS485 not RS232 60 GLD 2 fail GLD address 2 is failed Verify the GLD unit addressing and test GLD units individually on the GLD communication bus 61 GLD 3 fail One or more GLD units addres...

Страница 94: ...ue Full The Event Que is filled with more than 500 uncollected events Enable DCP timestamp polling on the master so events are collected or reboot the system to clear the alarm Table A 3 System Alarms...

Страница 95: ...e has several levels above it The full English name is as follows root iso org dod internet private enterprises dps Inc dpsAlarmControl dpsRTU Therefore dpsRTU s full object identifier is 1 3 6 1 4 1...

Страница 96: ...e set to 1 to perform the resync request which will resend TRAPs for any standing alarm Tbl B3 2 DisplayGrid points DisplayEntry 1 3 6 1 4 1 2682 1 4 2 1 Port 1 Address 2 Display 3 DispDesc 4 PntMap 5...

Страница 97: ...64 Disp 10 Analog 8 99 1 10 1 4 Undefined 99 1 10 5 64 Disp 11 Relays 1 8 99 1 11 1 8 Relays 9 16 99 1 11 9 16 Timed Tick 99 1 11 17 Exp Module Callout 99 1 11 18 Network Time Server 99 1 11 19 Accum...

Страница 98: ...hat the alarm point is defined but there is no description entered Undefined indicates that the alarm point is not used Appendix C SNMP Granular Trap Packets 4 3 Tables C 1 and C 2 provide a list of t...

Страница 99: ...6 0 Object 1 800 622 3314 Value 1 3 6 1 4 1 2682 1 4 4 1 0 Object 01 02 1995 05 08 27 760 Value 1 3 6 1 4 1 2682 1 4 5 1 1 99 1 1 1 Object 99 Value 1 3 6 1 4 1 2682 1 4 5 1 2 99 1 1 1 Object 1 Value 1...

Страница 100: ...surrounded by brackets e g IF A received BREAK will appear as BRK Abbreviatio n Description Abbreviatio n Description NUL Null DLE Data Link Escape SOH Start of Heading DC Device Control STX Start of...

Страница 101: ...ATTRIBUTE dps admin 1 integer ATTRIBUTE dps edit 2 integer ATTRIBUTE dps monitor 3 integer ATTRIBUTE dps SD monitor 4 integer To allow monitor of data port buffer activity ATTRIBUTE dps reach through...

Страница 102: ...om Inc Device Name NetGuardian 832A 864AG5 Highest DNP Level Supported For Requests Level 3 For Responses Level 3 Device Function o Master xSlave Notable objects functions and or qualifiers supported...

Страница 103: ...10s Complete Appl Response None Other Transmission Delay 0 Sends Executes Control Operations WRITE Binary Outputs Never SELECT OPERATE Never DIRECT OPERATE Always DIRECT OPERATE NO ACK Always Count 1...

Страница 104: ...nt Responses No Yes Sequential File Transfer Support No Append File Mode No Custom Status Code Strings No Permissions Field No File Events Assigned to Class No File Events Send Immediately No Multiple...

Страница 105: ...dir op noack 17 28 index 129 response echo of request 30 3 32 Bit Analog Input Without Flag 1 read 00 01 start stop 06 no range or all 129 response 00 01 start stop 50 1 Time and Date 1 read 07 limite...

Страница 106: ...1 64 95 Ping Targets 1 96 127 Unused 1 128 Timed Tick 1 129 Exp Module Callout 1 130 Network Time Server 1 131 Accumulation Event 1 132 Duplicate IP Address 1 133 WAN Disconnected 1 134 ECU Emergency...

Страница 107: ...1 161 Data 3 receive queue full 1 162 Data 4 receive queue full 1 163 Data 5 receive queue full 1 164 Data 6 receive queue full 1 165 Data 7 receive queue full 1 166 Data 8 receive queue full 1 167 Ne...

Страница 108: ...n codes supported 5 direct operate 6 direct operate no ack Supported relay output Latch on Latch off Point ID Description Class 0 Control 1 2 1 Control 2 2 2 Control 3 2 3 Control 4 2 4 Control 5 2 5...

Страница 109: ...codes supported 1 read Point ID Description Default Unit Class 0 Analog Channel 1 Voltage VDC 3 1 Analog Channel 2 Voltage VDC 3 2 Analog Channel 3 Voltage VDC 3 3 Analog Channel 4 Voltage VDC 3 4 An...

Страница 110: ...VDC 3 30 DX 3 Analog Channel 7 Voltage VDC 3 31 DX 3 Analog Channel 8 Voltage VDC 3 Appendix G Modbus Registers 4 7 Function Code Action 1 Coil Status Reads the current status of Relays 2 Input Statu...

Страница 111: ...6 3 11 Analog 6 Sign 7 16 3 12 Analog 7 Value 16 3 13 Analog 7 Scaling Range 1 16 3 16 3 13 Analog 7 Sign 7 16 3 14 Analog 8 Value 16 3 15 Analog 8 Scaling Range 1 16 3 16 3 15 Analog 8 Sign 7 16 See...

Страница 112: ...00 1315 NetGuardian E16 DX Expansion 1 Relay 1 16 2 1400 1415 NetGuardian E16 DX Expansion 2 Alarm 1 16 1 1500 1515 NetGuardian E16 DX Expansion 2 Relay 1 16 2 1600 1615 NetGuardian E16 DX Expansion 3...

Страница 113: ...nsion 3 Relay 1 8 Function Code Register Description 2 1200 1231 NetGuardian 832A as DX Expansion 1 Alarm 1 32 1 1300 1307 NetGuardian 832A as DX Expansion 1 Relay 1 8 2 1400 1431 NetGuardian 832A as...

Страница 114: ...101 NetGuardian 832 864 as DX Expansion 1 Analog 1 Scaling 1 16 3 16 3 101 NetGuardian 832 864 as DX Expansion 1 Analog 1 Sign 7 16 3 102 NetGuardian 832 864 as DX Expansion 1 Analog 2 Value 16 3 103...

Страница 115: ...pansion 1 Analog 5 Sign 7 16 3 110 NetGuardian 832 864 as DX Expansion 1 Analog 6 Value 16 3 111 NetGuardian 832 864 as DX Expansion 1 Analog 6 Scaling 1 16 3 16 3 111 NetGuardian 832 864 as DX Expans...

Страница 116: ...Expansion 2 Analog 1 Sign 7 16 3 202 NetGuardian 832 864 as DX Expansion 2 Analog 2 Value 16 3 203 NetGuardian 832 864 as DX Expansion 2 Analog 2 Scaling 1 16 3 16 3 203 NetGuardian 832 864 as DX Exp...

Страница 117: ...ion 2 Analog 6 Value 16 3 211 NetGuardian 832 864 as DX Expansion 2 Analog 6 Scaling 1 16 3 16 3 211 NetGuardian 832 864 as DX Expansion 2 Analog 6 Sign 7 16 3 212 NetGuardian 832 864 as DX Expansion...

Страница 118: ...uardian 832 864 as DX Expansion 3 Analog 2 Scaling 1 16 3 16 3 303 NetGuardian 832 864 as DX Expansion 3 Analog 2 Sign 7 16 3 304 NetGuardian 832 864 as DX Expansion 3 Analog 3 Value 16 3 305 NetGuard...

Страница 119: ...ardian 832 864 as DX Expansion 3 Analog 6 Sign 7 16 3 312 NetGuardian 832 864 as DX Expansion 3 Analog 7 Value 16 3 313 NetGuardian 832 864 as DX Expansion 3 Analog 7 Scaling 1 16 3 16 3 313 NetGuardi...

Страница 120: ...ardian 832 864 as DX Expansion 1 Analog 2 Scaling 7 16 4 104 NetGuardian 832 864 as DX Expansion 1 Analog 3 Value 16 4 105 NetGuardian 832 864 as DX Expansion 1 Analog 3 Scaling 1 16 3 16 4 105 NetGua...

Страница 121: ...832 864 as DX Expansion 1 Analog 7 Value 16 4 113 NetGuardian 832 864 as DX Expansion 1 Analog 7 Scaling 1 16 3 16 4 113 NetGuardian 832 864 as DX Expansion 1 Analog 7 Scaling 7 16 4 114 NetGuardian...

Страница 122: ...ardian 832 864 as DX Expansion 2 Analog 3 Value 16 4 205 NetGuardian 832 864 as DX Expansion 2 Analog 3 Scaling 1 16 3 16 4 205 NetGuardian 832 864 as DX Expansion 2 Analog 3 Sign 7 16 4 206 NetGuardi...

Страница 123: ...864 as DX Expansion 2 Analog 7 Scaling 1 16 3 16 4 213 NetGuardian 832 864 as DX Expansion 2 Analog 7 Sign 7 16 4 214 NetGuardian 832 864 as DX Expansion 2 Analog 8 Value 16 4 215 NetGuardian 832 864...

Страница 124: ...rdian 832 864 as DX Expansion 3 Analog 3 Scaling 1 16 3 16 4 305 NetGuardian 832 864 as DX Expansion 3 Analog 3 Sign 7 16 4 306 NetGuardian 832 864 as DX Expansion 3 Analog 4 Value 16 4 307 NetGuardia...

Страница 125: ...dian 832 864 as DX Expansion 3 Analog 7 Sign 7 16 4 314 NetGuardian 832 864 as DX Expansion 3 Analog 8 Value 16 4 315 NetGuardian 832 864 as DX Expansion 3 Analog 8 Scaling 1 16 3 16 4 315 NetGuardian...

Страница 126: ...can I back up the current configuration of my NetGuardian A There are two ways NGEdit can read the configuration of your NetGuardian and save the configuration to your PC s hard disk or a flash drive...

Страница 127: ...but the changes did not seem to take effect even after I wrote the NVRAM A In order for data port and craft port changes including changes to the baud rate and word format to take effect the NetGuardi...

Страница 128: ...ide SNMP managers with a single MIB for all DPS Telecom products Q How many traps are triggered when a single point is set or cleared The MIB defines traps like major alarm set cleared RTU point set a...

Страница 129: ...your pager number First enter the pager number then enter some commas directly after the number Each comma represents a two second delay So for example if you wanted an eight second delay you would e...

Страница 130: ...formation when you call our Technical Support representatives can assist you in gathering it Please write the information down for easy access Please have your user manual and hardware serial number r...

Страница 131: ...old it harmless for and against any and all claims damages losses costs expenses obligations liabilities fees and costs and all amounts paid in settlement of any claim action or suit which may be asse...

Страница 132: ...127...

Страница 133: ...lightning unless and to the extent that the product specification provides for resistance to a defined disaster e damage caused by unauthorized attachments or modifications f damage during shipment fr...

Страница 134: ...duct manuals Product datasheets Exclusive user forms Expert tips on using your alarm monitoring equipment advanced techniques that will save you hours of work Educational White Papers deliver fast inf...

Отзывы: