P a g e w w w . a n t h o n y i n t l . c o m
The seven individual wires extending from the flexible conduit atop the frame, provide electrical power to various frame and door functions
for the wiring diagram label, affixed to the frame header.
Using wire connectors, these wires should be grouped by the Hotwires (Circuit wires), the Neutral wires, and the ground wire for connection
to either the facility or the case power.
•
Blue/White wire connects to the supplied Hot (or Lights Circuit Wire).
•
White/Blue wire connects to the supplied Light neutral wire.
•
Red and Black wires connect to the supplied Hot (or Door/Frame Heater Circuit Wire).
•
White/Red and White/Black wires connect to the supplied neutral wire for the Door/Frame Circuit.
•
Green/Yellow wire connects to the supplied ground wire.