![Dover Anthony Complete 101 Series Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/dover/anthony-complete-101-series/anthony-complete-101-series_installation-manual_2524816061.webp)
Complete 101 Series Installation Manual
99-25517-I001 July 2022 Rev. B
60 |
P a g e w w w . a n t h o n y i n t l . c o m
Replacing the Hold-Open Assembly
1.
Insert the pivot standoff into the door.
2.
Add Loctite #271 to threads. Torque to 100 in/lb.
3.
Place the pivot hole of the new hold open over the pivot standoff that is closest to the hinge pin.
4.
Retain with a new truss head screw and torque to 16 in/lb. (approximately #2 clutch setting on a professional screw gun).
5.
Remove the vinyl cap from the detent bolt.
6.
Insert the bolt up thru the hold open slot and then thru the detent spacer (flat side against frame).
7.
Add Loctite #271 to threads. Use a 7/16 hex wrench and torque into the frame to 100 in/lb.
8.
Add a small amount of grease to the detent surface.
9.
Ensure the truss head screw is seated on the end of the standoff and not the hold open.
Figure 14.2 Hold-open Assembly