Frame Electrical Wiring Connections
The electrical connection at the Junction Box where the wires enter the frame, and where the wires enter the raceway in the frame must be
sealed with silicone caulking at the time of installation.
WARNING
Stop:
Wiring for lights should have a separate circuit from the door/frame heater wiring
circuit.
WARNING
Warning –
To reduce the risk of fire, electrical shock or injury observe the following:
- Use this unit in the manner intended by the manufacturer.
-
Turn the power off before removing the existing lighting system and follow
appropriate lockout/tag-out safety procedures
WARNING
Risk of Electrical Shock–
Potential risk of Electrical Shock; pay close attention to instructions
when performing this and any other associated tasks.
Conduit Exit Location
For walk-in frames, the conduit exit for connection wires is typically located on the top right inside of the frame. Depending on your needs
when ordering you can designate where you would prefer the conduit exit to be located. Frame Junction box location is determined by
customers.
Figure 2.10: Conduit Exit location