![Dover Anthony Complete 101 Series Скачать руководство пользователя страница 44](http://html1.mh-extra.com/html/dover/anthony-complete-101-series/anthony-complete-101-series_installation-manual_2524816044.webp)
Complete 101 Series Installation Manual
99-25517-I001 July 2022 Rev. B
43 |
P a g e w w w . a n t h o n y i n t l . c o m
Recommended Maintenance Inspection and Cleaning Intervals
Action
Store Conditions
Description
Preventative Inspection
Normal Conditions
Once each quarter (every 3 months)
Harsh Conditions
Once a month (every 30 days)
Cleaning
All Conditions
Once a month (every 30 days)
Note: These are recommendations based on historical data of other Anthony door products and can vary depending on location, store conditions, store traffic, and other
unknown variables.
Maintenance Recommendations
Here is an outline of standard recommend inspection interval recommendations:
•
Freezer/Cooler Temp & Defrost Settings
–
Regularly inspect and ensure that ambient conditions are correct, refer to the values
that pertain to your specific Door Model for Operating Condition values that are required for optimal door performance, and to
maximize door and frame longevity
.
•
Frame & Door
– Regularly ensure to check for wear/tear on frame and door this can include:
o
Ensuring that warning labels and product identification labels are all intact
o
Ensure all Bezels are intact and not damaged
o
Ensure that Vents are clean and allow maximum Airflow
o
Ensure all plastic backs are secured and undamaged
o
Handles are secured to the door
o
Ensure the door is opening to the angle of 87°
o
Rails are intact, not broken, and securely in place
•
Door/Frame Hinging Pin & Receptacle Area
–
Regularly ensure to check for wear/tear all hinging parts include:
o
Inspect that the Hinge Pin is properly connected with the frame receptacle,
DO NOT
remove the factory-installed dielectric
grease from the Hinge Pin assembly to ensure the proper function
o
Inspect that the Hinge Pin and receptacle are rust/corrosion free, and there is an adequate amount of Dielectric Grease
present
o
If when replacing or servicing Door and it is removed from the Hinge Pin receptacle, ensure to re-apply dielectric grease
before installation of the door
o
Anthony recommends applying a minimum of three (3) grams per door Hinge Pin receptacle of its
High-performance Dielectric Grease
(Refer to the specific door model’s installation manual for more detailed instructions on how to apply
):
-
Anthony P/N:
98-25497-0001
(approximately 100 grams, sufficient for up to 30 door receptacles).
-
Anthony P/N:
98-25497-0002
(approximately 3-gram packet, sufficient for up to 1 door receptacle).
o
Replace any broken or damaged Hinge Pin and ensure to apply an adequate amount of Dielectric Grease
o
Visually and mechanically Inspect Hold-Open Arm, Screw, and Spacer for wear/tear/damage and that Screw it is secure
•
TorqueMaster™
–
To check the TorqueMaster™ is functioning correctly open each door and ensure that the tension makes the
door close smoothly and gently on its own. If the door closes either too slowly or rapidly the issue can be fixed by adjusting that
Torque Master™ refer to the “Torque Master™ and Sag Adjustment” section for details. If after adjusting the issue is still present
the next step is to replace the Torque Master™, refer to this manual for detailed instructions on replacing.