9
06.3 Operation with V-mount battery
(optional)
V-mount Li-Ion batteries are optionally available from DÖRR.
See capture
10 | OPTIONAL ACCESSORIES
.
CAUTION
Before operating with V-mount battery,
make sure that the control unit is switched
off (main switch (8) on position O = off ) and
then disconnect the power supply from the
control unit. To disconnect the plug, always
press the release button!
1. Slide the V-mount battery into the V-mount (13) until the battery clicks into place.
Pay attention to the battery co/- (15).
2. Turn on the LED Flex Panel with the main switch (8) at the control unit:
Main switch (8)
position I = Operation with V-mount battery
3.
Before removing the V-mount battery, turn the control unit off (main switch (8) on
position O).
Press the release button (14) and slide out the battery.
06.4 Dimming
By turning the brightness control knob (10) the brightness can be dimmed in steps.
CAUTION
After use please turn off the LED fl ex panel (main switch 8 = position O).
07 |
CLEANING AND STORAGE
Never use aggressive cleansing agents or benzine to clean the device. We recommend
a soft, slightly damp microfi ber cloth to clean the outer parts of the device and the LED
surface.
Make sure to take off the device from power before cleaning!
Store the device
in a dust-free, dry and cool place. This device is not a toy – keep it out of reach of child-
ren. Keep away from pets.
05 |
MOUNTING
X-Frame
Unfold the X-frame (6) and insert the rods
into the fastening corners (5). With the
light stand adapter (7) the LED Flex Panel
can be mounted horizontally or vertically
onto a light stand (optional) and it is in-
clinable.
Velcro mounting straps
With the various Velcro straps (20), the
LED Flex Panel can be attached to the wall,
to the ceiling etc. or you can connect seve-
ral LED Flex Panels with each other.
06 |
OPERATION
CAUTION
Before connecting or disconnecting cable connections, make sure that the control unit is
switched off (main switch (8) on position O = off ).
06.1 Power connection
Plug the connection cable of the LED Flex
Panel (2) into the connection cable of the
control unit (11). Pay attention to the pins
and holes. Screw the blue cap down.
To
disconnect the cable connection, un-
screw the blue cap fi rst!
06.2 Operation with power supply
1. Plug the connection cable (16) of the
power supply into the power socket (9)
of the control unit, until the plug audibly
clicks into place. Pay attention to the
pins and holes.
To disconnect the plug,
always press the release button!
2. Plug the power cable (18) into the power
cable socket (17) and connect the
power supply to a socket outlet.
3. Turn on the LED Flex Panel with the
main switch (8) at the control unit: Main
switch (8)
position II = Operation with
power supply
Hint
With the suspension cord (12) or with the supplied Velcro strap with V-mount adapter (19)
you can attach the control unit e.g. to a light stand (optional) or fi x the power supply to
the control unit. Just slide the V-mount adapter (19) into the V-mount (13). Use the Velcro
straps to hold the control unit or to fi x the power supply. To remove the V-mount adapter,
press the release button (14).
Model
FX-3040 DL
FX-4555 DL
Item No.
373620
373625
Number of LEDs
280/white
504/white
Colour temperature
5600 K
Power
34 W
62 W
Beam angle
10 - 360°
Colour rendering index (CRI)
95 R
a
Illuminance
0,5 m: 3680 Lux
0,5 m: 6940 Lux
1,0 m: 1230 Lux
1,0 m: 2470 Lux
Operating voltage
DC 15 V 5A
Operation with
Power supply AC 100 ~ 240 V 50/60 Hz
(included)
or V-mount Li-Ion battery
(optional)
Dimensions
approx. 315x 450 x10mm approx. 460x600 x10mm
Dimensions illuminated area
approx. 300 x 395 mm
approx. 445 x 545 mm
Weight LED panel
approx. 288 g
approx. 440 g
Weight control unit
approx. 500 g
Weight power supply incl. power cable
approx. 395 g
08 |
SPECIFICATIONS