APPENDIX A.1 Reversing the Mortise Handing
on ASM 1 1/4" Face Plate Only
A.1.1 Reversible ASM
1. Place the mortise on a flat surface.
2. Partially extend the deadbolt:
For normal ASM, rotate hub (D4) using a screwdriver, until
the deadbolt (D5) extends approximately 1/4".
D5
1/4"
D4
Proceed to step 3.
For Autodeadbolt ASM,
rotate hub (D4) until the deadbolt
(D5) is fully retracted. The deadbolt will extend approx. 1/16"
from the mortise case.
D5
1
/
16
"
D4
Hold the deadbolt (D5) gently. Press and release the auxiliary
latch (D6). You should feel the deadbolt trigger and begin to
extend under the force of the spring.
D5 (hold
gently)
D6 (press and
release)
Release the deadbolt (D5) gently. It should extend to approxi-
mately 5/16" and stop. If the deadbolt extends past this point,
gently press it in until it locks at a protrusion of approximately
5/16" or start step 2 again.
D5
5
/
16
"