105
ED900
02-2020
08125330
dormakaba ED900 Installation Instructions – Double egress door
Appendix A
Parameter
Value
range
Units
Factory
setting Description
Door closer mode
34
0 - 1
1
0
1. Automatic mode. This mode is applicable whenever door is mainly opened
automatically and where motion detectors are installed.
2. Mode is optimized for high frequency use.
3. Full energy upgrade card provides for higher door opening and closing speeds.
4. In case door is blocked during a closing cycle, operator reverses automatically.
5. Driving phase is optimized to provide reliable closing cycles.
6. Keep closed force (wind load control) parameter
FH
and Push & Go function
parameter
PG
are only available in automatic mode.
1
1. Manual mode. This mode is applicable whenever door is mainly used manually
and only rarely automatically.
2. In case door is blocked during a closing cycle, door will stop at its current position.
3. Driving phase optimized for manual opening cycles.
4. Power assist function parameter
hf
is only available in manual mode.
Power assist activation angle
1. Setting of door activation angle for Power assist function (
hF
).
2. Higher settings of
hA
result in better spring force compensation for easier manual
opening.
3. Power assist function is more sensitive the smaller the activation angle.
35
1 - 5
°
3
Power assist function
1. Force setting for Power assist function.
2. Power assist function only available with
hd
parameter = 1, manual mode.
3. "0"; power assist function OFF; power assist function enabled for available values
greater than 0.
4. Power assist function enabled when power assist activation angle
hA
reached.
5. The greater the value of
hF
, the easier the door can be manually opened from power
assist activation angle
hA
.
6. If power assist set too high, door can open automatically.
7. Power assist function is not available
• If operator is switched off
• A smoke detector or emergency button has been triggered.
36
0 - 10
0
Power assist function support for manual
mode in door closed position
1. Setting for power assist function support with door in
closed
position.
2. Power assist function only available with
hd
parameter = 1, manual mode.
3. The greater the value of
hS
, the easier the door can be manually opened from the
closed
position.
37
0 - 10
0
hS
Upgrade card units codes
0 - 3
0
0
Upgrade card not installed, function not available.
1
Upgrade card installed, function not activated.
2
Upgrade card installed, function activated.
3
Upgrade card has been removed, function no longer available.
Upgrade card, fire protection
1. Once upgrade card installed, parameter value will automatically change to 2.
2. Following activation, drive may be used as a electrically controlled hold-open system
according to EN 14637, Building hardware-Electrically controlled hold-open systems for
fire/smoke door assemblies, or similar standards.
3. Full energy function is automatically activated.
4. Plug for terminal board X9 socket included with upgrade card.
38
0, 2, 3
0
A.1.1 Driving parameters detail.