background image

9000-065-J-9-11

27

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

1

ON

SW 1

2

3

4

1

ON

SW 2

REVERSE
LOOP

P2

P8

EXIT
LOOP

SELF
TEST

NC

TIME
DELAY

NO

REV SENSE
PRIMARY

REV SENSE
SECONDARY

1

2

3

4

5

6

7

8

9

13

12

11

10

14

15

16

17

18

19

20

2

3

4

5

6

7

8

4405-010

Note: The 6-pin terminal can be unplugged 
from circuit board for easy wire connections.

All inputs are normally open (NO).

6-Pin UL 325 Terminal

Secondary Entrapment Protection Device Connection

115 VAC Convenience Outlets

Secondary Entrapment Protection Devices:

In addition to the inherent reversing sensor system, the Model 9000 has a 6-pin UL 325 terminal for the connection of 

photo sensors

-Type B1 

and 

reversing edges

-Type B2 secondary entrapment protection devices required by UL 325 standards. Entrapment protection devices 

must 

be installed

 to reduce the risk of injury. Install these devices where the risk of entrapment or obstruction exists while the gate is moving.

The Model 9000 offers numerous options to meet your specific needs. The next 2 pages show wiring and typical positioning of the entrapment 
protection devices but specific installations will vary.

Note:

 Secondary entrapment protection devices will open the gate to the “Partial Open” setting when the opening device is connected to main 

terminal #5 (See page 32 for opening device wiring information).

OPEN Entrapment Sensor

CLOSE Entrapment Sensor

OPEN Contact Sensor

CLOSE Contact Sensor

Low Voltage Common

Low Voltage Common

SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION

4.1 UL 325 Terminal Description

1
2
3
4
5
6

Closed Gate

Wall / Fence

Opening-Direction Photo Beam

Wall / Fence

Filler Post if necessary

Gate Support Post if Installed

Closed Gate

Wall / Fence

Closing-Direction Photo Beam

Closed Gate

Wall / Fence

       CLOSE Entrapment Sensor (Photo Sensor):

 

Obstructed 

closing-direction photo beam will stop the gate 

during the 

closing-direction only.

 Gate will resume the close cycle 

when the obstructed photo beam has been cleared.

Closed Gate

               Low Voltage Common:

 

Common terminals for all the secondary entrapment protection device inputs.

       CLOSE Contact Sensor (Reversing Edge):

 

Obstructed closing-direction reversing edge will stop, then reverse the gate to the open position, 

during the 

closing-direction only.

 • 

After the gate reverses to the open position, the timer will 

    automatically close the gate (if it is turned on). If the 
    closing-direction reverse edge is activated a 

second

 time prior to the gate reaching the 

    close position, the operator will 

stop

 and enter a soft shutdown condition (See page 34).

 • 

When the 

closing-direction

 reversing edge gets obstructed and the gate is traveling back to the open 

    position and the 

opening-direction

 revering edge gets obstructed, the gate will 

stop

 and enter a soft shutdown condition (See page 34).

1

2

3

4

&

 6

       OPEN Entrapment Sensor (Photo Sensor):

 

Obstructed 

opening-direction photo beam will stop the gate 

during the 

opening-direction only.

 Gate will resume the open cycle 

when the obstructed photo beam has been cleared.

       OPEN Contact Sensor (Reversing Edge(s)):

 

Obstructed opening-direction reversing edge(s) will stop, then reverse the gate to the close position 

during the 

opening-direction only.

 • 

After the gate reverses to the full close position, any 

    opening input will cycle the gate again. Note: If the gate is 
    opening by a time clock and an opening-direction reversing 
    edge gets obstructed, the gate will return to the closed 
    position and another input (automatic exit loop, reverse loop. etc.) is needed to cycle the gate open 
  again.

 • 

When the 

opening-direction

 reversing edge(s) gets obstructed and the gate is traveling back to the close position and 

  the 

closing-direction 

reversing edge gets obstructed, the gate will 

stop

 and enter a soft shutdown condition (See page 34).

Opening-Direction Reversing Edges

Closing-Direction Reverse Edge

Entrapment Area

Entrapment Area

Entrapment Area

Entrapment Area

Содержание 9000-080

Страница 1: ...an au tomatic clos ing de vice suc h as a tim er loop se ns or or simila r de vice sh all no t be em ploy ed SERIO US IN JURY OR DEATH CL AS S CE RTIFIED TO CA N C SA C2 2 2 NO 24 7 CO NFO RMS TO AN S...

Страница 2: ......

Страница 3: ...DEL SERIAL VOLTS PHASE AMPS 60 Hz MAX GATE LOAD DoorKing Inc Inglewood CA SPECIFICATIONS Gate Frame 7 75 4 Minimum Chain Height Idler wheels in top position Concrete Pad Concrete Pad Class of Operatio...

Страница 4: ...6 16 17 18 18 1 1 Hardware for the Gate 1 2 Underground Conduit Requirements 1 3 Gate Types 1 4 Operator Mounting Positions 1 5 Concrete Pad Setup or Optional Post Mount Kit 1 6 Positioning Operator a...

Страница 5: ...In Diagnostics 7 3 Troubleshooting 7 4 Accessory Items Model 9000 115 VAC Wiring Diagram 36 36 37 38 39 40 SECTION 6 OPERATING INSTRUCTIONS 33 6 1 Operator Controls and Resets 6 2 Shutdown Conditions...

Страница 6: ...eparate access opening The pedestrian access opening shall be designed to promote pedestrian usage Locate the gate such that persons will not come in contact with the vehicular gate during the entire...

Страница 7: ...and maintained serious injuries or death can result Be sure that the installer has instructed you on the proper operation of the gate and gate operator system Be sure that the installer has trained y...

Страница 8: ...in which unauthorized access is prevented via supervision by security personnel This table illustrates the entrapment protection requirements for each of the four UL 325 classes A Inherent entrapment...

Страница 9: ...or vehicular traffic flow at entrances or exits to areas such as parking garages lots or toll areas VEHICULAR HORIZONTAL SLIDE GATE OPERATOR OR SYSTEM A vehicular gate operator or system that controls...

Страница 10: ...ier may need to be installed in the gap area to reduce the distance to 2 1 4 inches or less A contact sensor should be installed in this area for safety See on next page and page 28 A gap measured in...

Страница 11: ...EEP CLEAR Gate may move at any time without prior warning Do not let children operate the gate or play in the gate area This entrance is for vehicles only Pedestrians must use separate entrance Separa...

Страница 12: ...minimize a pinch point for a 180 chain return Guide Rollers with Protective Covers Helps to minimize a pinch point on the gate Roller Bearing V Wheels with Protective Cover Helps to minimize a pinch...

Страница 13: ...HP motor Chain tray recommended for gates over 20 ft Post mount installation when using a chain tray Single operator 35 ft max gate length Dual operators 70 ft max gate length Box Frame Cantilever V...

Страница 14: ...ps Once the mounting position has been selected refer to pages 15 thru 18 for specific installation instructions Top View Idler Wheels and Chain Setup Top View Idler Wheels and Chain Setup Set operato...

Страница 15: ...center and one in the bottom position Set one chain Idler wheel at the top and one in the center position Idler Wheels and Chain Setup Endless Idler Additional hardware required Post mount kit P N 900...

Страница 16: ...to attach to gate This is useful with long gates It supports the chain s weight and helps prevent chain stretching Gate in Close Position Endless Idler Endless Idler Gate in Open Position Gate shown i...

Страница 17: ...specifically for the Model 9000 P N 9000 015 The kit includes a base plate 2 posts and hardware to attach the operator to the base plate This kit will raise the operator and allow different chain hei...

Страница 18: ...ghten the chain Operator and chain are NOT parallel to gate Chain bracket does NOT align with idler wheels Chain bracket MUST line up with chain idler wheels Chain brackets MUST be mounted so the chai...

Страница 19: ...perator Idler Wheel Lower chain mounted Too High Lower chain mounted Too Low NO NO Lower chain mounted Too High Lower chain mounted Too Low DoorKing offers an endless idler assembly with a protective...

Страница 20: ...ppropriate hardware such as wood or sheet metal screws not supplied to install the warning signs 1 9 DoorKing s Chain Tray Kit The Chain tray supporting brackets can be mounted facing up as shown or f...

Страница 21: ...1 2 HP 115 VAC Single Phase 1 2 HP 208 230 VAC Single Phase 1 2 HP 460 VAC Single Phase 1 HP 115 VAC Single Phase 1 HP 208 230 VAC Single Phase Never run low voltage rated wire insulation in the same...

Страница 22: ...e gate area This entrance is for vehicles only Pedestrians must use a separate entrance Persons are to read the owner s manual and safety instructions For gate operator using Type D entrapment protect...

Страница 23: ...separately Limit Switch Plug P2 6 Pin UL 325 Removable Terminal See page 27 1 23 EXIT Loop Terminal REVERSE Loop Terminal Self Test Auto Close Timer How LEDs Function DIP Switches Adjust reversing sen...

Страница 24: ...ed Magnetic lock is used and connected to terminals 9 and 12 See page 32 for wiring Opening direction using ON setting Opening direction using OFF setting Changes direction operator will cycle open up...

Страница 25: ...ating vehicle will stop partially or completely blocking the pathway NOT allowing the tailgating vehicle to enter without proper authorization The gate will not move until all sensors are clear usuall...

Страница 26: ...om the limit nuts Rotate the limit nuts to the desired gate FULL open and close positions After adjusting make sure the lock plate is engaged in the slots on the limit nuts to prevent them from rotati...

Страница 27: ...ely in both directions and the limit switches must be properly adjusted before adjusting these sensors The ideal adjustment will allow the operator to move the gate through its entire travel cycle wit...

Страница 28: ...ower Secondary Current Sensor located only in primary operator Typical Number of Turns for Secondary Current Sensor Primary Operator Automatic Exit Reverse WAR NING MOVING GATE CAN CAUSE Persons are t...

Страница 29: ...top the gate during the closing direction only Gate will resume the close cycle when the obstructed photo beam has been cleared Closed Gate Low Voltage Common Common terminals for all the secondary en...

Страница 30: ...on Photo Sensor Power Note Photo sensors can be powered by the built in convenience outlets located on the operator See previous page IF the closing direction photo sensor is wired to the 6 main termi...

Страница 31: ...Terminal Wiring Opening Direction Reversing Edge If filler post is used 9 V battery operated transmitter mounted on gate Filler Post If necessary Edge Transmitter Edge Transmitter Power is limited to...

Страница 32: ...g vehicles without having to use a transmitter or keypad The exit loop can be placed a minimum of 4 feet away from the reverse loop or far enough away from the gate so the gate has started opening or...

Страница 33: ...be set for Normally Open NO or Normally Closed NC operation Contact rating is 1 amp maximum at 24 volts DC NO NC SW 1 1 ON 2 3 4 5 6 7 8 SECTION 5 MAIN TERMINAL WIRING This input ONLY functions when...

Страница 34: ...witch together 3 terminal N C must be wired in series Remote Alarm Reset Station DKS P N 1404 080 MUST be mounted in the line of sight of the gate operator 3 Button Control Station Use a standard 4 wi...

Страница 35: ...STRUCTIONS WARNIN G MO VIN G GA TE CA N CA US E Pers ons are to keep clea r The gate is capa ble of bein g mov ed with out prio r warn ing Do not let child ren oper ate the gate or play in the gate ar...

Страница 36: ...the open position If the inherent entrapment protection gets activated during this opening cycle the gate reverses and runs back to the closed position After the inherent entrapment protection is cle...

Страница 37: ...ate any gate until you have verified that power to the operator has been shut off Pull Manual Release Handle Pull straight OUT as far as possible and then UP Manually Push Gate Open 1 Release Handle W...

Страница 38: ...indicates that the operator is in a hard shutdown condition The alarm will continue to sound for five minutes and then will chirp once every five seconds The operator reset button must be pressed or p...

Страница 39: ...from the control board to the motor or a bad control board If the motor runs in both steps above contunue troubleshooting control board and accessories Operator will not run Power LED is ON 1 Check th...

Страница 40: ...tive LED on the control board lights when the keying device connected to the respective terminal is activated If LED does not light momentarily place a jumper wire from terminal 1 to the input termina...

Страница 41: ...NOT provided P N 1204 004 Post Mount Kit for 9000 Required for post mount installation P N 9000 015 Chain Tray Kit 10 Ft section Sections connect together to fit any length gate P N 2601 270 Additiona...

Страница 42: ...ets Alarm Secondary Operator Current Sensor 115 VAC NEU HOT Gray Gray Gray Gray Red Red White Black Black Black Black Blue Blue Blue Red Red Red Red Orange Orange Yellow Yellow Yellow Orange White Whi...

Страница 43: ...9000 065 J 9 11 41...

Страница 44: ...ght 2009 DoorKing Inc All rights reserved Use this manual for circuit board 4405 010 Revision D or higher www doorking com Vehicular Slide Gate Operator DoorKing Inc 120 Glasgow Avenue Inglewood Calif...