5
BIOCLASS iC 66
13 TECHNICAL MENU .................................................................................................................. 50
13.1
E
NTRY AND SET THE ACCESS CODE
("
COD
",
P.25) ......................................................................................... 54
14 BOILER'S SETUP PARAMETERS ............................................................................................... 55
14.1
B
OILER
M
ODEL
(P.01) .......................................................................................................................... 55
14.2
B
OILER HEAT OUTPUT
(P.02,
P.03) .......................................................................................................... 55
14.3
G
ENERAL FAN SPEED FACTOR
(P.04) ......................................................................................................... 55
14.4
F
UEL FOR IGNITION
(P.05) ..................................................................................................................... 55
14.5
F
UEL CONSUMPTION
(P.06) .................................................................................................................... 55
14.6
M
ANAGING
BT
AND
BT-DUO
BUFFER TANKS
(P.08,
P.28,
P.50) ..................................................................... 56
14.7
A
UXILIARY PARAMETER FOR FUEL SELECTION
(P.26) ...................................................................................... 56
14.8
B
OILER MINIMUM TEMPERATURE MODE
(P.13,
P.14) ..................................................................................... 56
15 HEATING CIRCUIT'S SETUP PARAMETERS ............................................................................... 57
15.1
H
EATING PUMP POST
-
CIRCULATION TIME
(P.15) ........................................................................................... 57
15.2
B
OILER
'
S PUMP OPERATING MODE
(P.18) ................................................................................................... 57
15.3
M
INIMUM BOILER WATER PRESSURE
(P.19) ................................................................................................. 57
15.4
T
YPE OF ROOM TEMPERATURE DEVICE
(P.46,
P.47,
P.48) .............................................................................. 57
15.5
R
OOM TEMPERATURE HYSTERESIS
(P.49) ................................................................................................... 58
15.6
R
OOM TEMPERATURE CORRECTION
(P.51,
P.52,
P.53) .................................................................................. 58
16 DHW CIRCUIT'S SETUP PARAMETERS ..................................................................................... 59
16.1
DHW
INSTALLATION MODE
(P.09) ........................................................................................................... 59
16.2
DHW
PUMP POST
-
CIRCULATION TIME
(P.16) .............................................................................................. 59
16.3
L
EGIONELLA PROTECTION FUNCTION
(P.17) ................................................................................................ 59
16.4
DHW
RE
-
CIRCULATION FUNCTION
(P.20
=
2) ............................................................................................. 59
17 ADDITIONAL FUNCTIONS ....................................................................................................... 60
17.1
T
IME OF THE
F
UEL SUCTION SYSTEM CYCLE
(P.22) ........................................................................................ 60
17.2
R
ESET DEFAULT VALUES
(P.24) ............................................................................................................... 60
17.3
P
UMPS ANTI
-
LOCK FUNCTION
................................................................................................................... 60
17.4
A
NTI
-
FROST FUNCTION
.......................................................................................................................... 60
17.5
B
OILER PRESSURE SENSOR FUNCTION
......................................................................................................... 60
17.6
C
ONNECTING THE
LAGO
FB
OT+
REMOTE CONTROL
..................................................................................... 60
17.7
R
OOM THERMOSTAT CONNECTION
............................................................................................................. 61
17.8
C
ONNECTING THE ROOM SENSOR
.............................................................................................................. 61
18 MULTI-FUNCTIONAL RELAY (P.20) .......................................................................................... 62
18.1
B
OILER ALARMS EXTERNAL SIGNAL
(P.20
=
1) ............................................................................................. 62
18.2
DHW
RE
-
CIRCULATION FUNCTION
(P.20
=
2) ............................................................................................. 62
18.3
A
UTOMATIC WATER FILLING FUNCTION
(P.20
=
3) ....................................................................................... 62
19 SAFETY LOCK-OUTS ............................................................................................................... 63
19.1
T
EMPERATURE SAFETY LOCK
.................................................................................................................... 63
19.2
F
UEL ENTRANCE TUBE OVERHEAT SAFETY CUT
-
OUT
........................................................................................ 64
19.3
L
OW PRESSURE LOCK
-
OUT
...................................................................................................................... 64
20 SHUTTING DOWN THE BOILER ............................................................................................... 64
21 EMPTYING THE BOILER .......................................................................................................... 64
22 BOILER MAINTENANCE ........................................................................................................... 65
22.1
F
REQUENCY OF MAINTENANCE OF THE BOILER AND CHIMNEY
............................................................................. 65
22.2
B
URNER CLEANING PROCEDURE
................................................................................................................ 65
22.3
H
EAT EXCHANGER CLEANING PROCEDURE
.................................................................................................... 67
22.4
D
RAINING THE CONDENSATE WATER
.......................................................................................................... 68
22.5
B
OILER WATER CHARACTERISTICS
............................................................................................................. 68
23 DIAGRAMS AND MEASUREMENTS ........................................................................................... 69
24 CONNECTIONS DIAGRAM ....................................................................................................... 70
24.1
B
OILER
............................................................................................................................................. 70
24.2
B
URNER
............................................................................................................................................ 71
24.3
E
LECTRICAL DIAGRAM
............................................................................................................................ 72
25 TECHNICAL DATA .................................................................................................................. 73
26 ALARM CODES ....................................................................................................................... 75
Содержание BioClass iC 66
Страница 1: ...Bioclass iC 66 Biomass boiler EN INSTALLATION AND OPERATING INSTRUCTIONS ...
Страница 2: ......