EN
44
BIOCLASS iC 66
11.6
Time setting
When “Time setting” parameter of “Setup menu” is displayed, press
to access. The first two digits
of numerical digits blinks (hours) and setting process begins:
Set the hour value by pressing “+" or "-" of DHW (19). Pressing
the value is saved and the minutes
digits blinks to set them.
Set the minutes value by pressing “+" or "-" of DHW
(19)
. Pressing the value is saved and it returns
to "Setup menu" level.
When the boiler is registered in
iConnect
, it will not be necessary to set the time as it will be
automatically set and synchronised by the APP, so this screen from the "Configuration" menu will not
be displayed.
11.7
Empty ash box notice
With this function activated, the boiler lets us know when the boiler ash box is full, so that we proceed
with its emptying. The parameter “Ashtray status” of “User Menu” allows checking the actual fill level.
When it is full, an "Empty the ashtray" warning is activated.
By default, the ash box reminder function is supplied activated and is set to indicative fuel consumption
values which, depending on the quality and type of fuel, will have to be adjusted for each system.
Below shows the default number of kilograms at which the boiler notifies you to empty the ash drawer:
Modelo
kg
BioClass iC 66
6000 kg
Select
“Ashtray empty warning”
(
) parameter of
“Setup menu”
and
press
to access. The value is set by pressing "
+
" and "
-
" symbols
of DHW
(19)
. It is possible to deactivate this function by setting the
value of this parameter to "
OFF
".
NOTE: Each time a new value is set for this parameter, the ashtray must be emptied.